Working principle and features:
The fan coil unit (FCU as below) have no energy itself but through pipeline of central air conditioner supplying with chilled or cooled water into the copper tube of heat exchanger inside house, and the fan blow through the heat exchanger to cool or heat the temperature of the house. The FCU is characterized with energy-saving, high efficiency, low noise, reliable and convenient to select and install.
Application scope
The unit is widely used together with central air conditioning system in hotel, hospital, medicine factory, theater, commercial building, office building, enterprises, chemical industry, exhibition room, research institutes and so on.
Rating capacity:
Cooling:Inlet air dry-bulb temperature 27'C;wet-bulb temperature 19.5'C;inlet water temperature 7'C;outlet water temperature 12'C.Heating:Inlet air dry-bulb temperature 21'C;Cooling water inlet temperature 60'C; working pressure:1.6MPa.
Size:FP-136 LZ,170 LZ,204 LZ,238 LZ.
Tube size:inlet/outlet water pipe RC3/4 Condensing drain pipe R3/4
Installation, use and maintenance
Working principle and features:
The fan coil unit (FCU as below) have no energy itself but through pipeline of central air conditioner supplying with chilled or cooled water into the copper tube of heat exchanger inside house, and the fan blow through the heat exchanger to cool or heat the temperature of the house. The FCU is characterized with energy-saving, high efficiency, low noise, reliable and convenient to select and install.
Application scope
The unit is widely used together with central air conditioning system in hotel, hospital, medicine factory, theater, commercial building, office building, enterprises, chemical industry, exhibition room, research institutes and so on.
Rating capacity:
Cooling:Inlet air dry-bulb temperature 27'C;wet-bulb temperature 19.5'C;inlet water temperature 7'C;outlet water temperature 12'C.Heating:Inlet air dry-bulb temperature 21'C;Cooling water inlet temperature 60'C; working pressure:1.6MPa.
Size:FP-35DLM,40DLM.
Tube size:inlet/outlet water pipe RC3/4 Condensing drain pipe R3/4
Installation, use and maintenance
GK Series cabinet air conditioning unit, referencing JB/T9066-1999 standards, was state of the art air-conditioning units developed to meet user requirements. According to user requirements, heating, cooling, humidification, filtration sterilization, and other evolutionary function can easily be realized.
It is widely used in hotels, shopping malls, airports, hospitals, office buildings and other public buildings. It also can be used for the industries of electronics, textiles, chemicals, pharmaceutical, food and so on. GK Series air conditioning unit not only has the superior performance on cooling and heating, featuring low noise, reasonable structure, light weight, easy installation and maintenance, but also can be adjusted to control the air flow to meet any demand of the building which space is limited.
Characteristic:
Alloy frame:filled with polyester foam.
Fan:Adopt centrifugal fan which features low noise and vibration
Chiller:Manufactured based on ARI Std.Test under the pressure of 2.8Pa to guarantee good capability and quality.
Drip tray:The Tray need to be installed with a little angle to benefit the water flow.
Inhaler:Specially designed filter can be conveniently drawn out from top to bottom, which is particularly convenient to maintain within limited space. Filter material may be nylon or others.
The product synopsis Air exchanger is one kind of system to treat feculent air by the filtration, the purification, the heat exchanging processing evacuation, simultaneously handle the fresh air after the filtration, the purification, the heat change processing to keep indoor temperature unchanged to realize inside and outside air change bidirectional. The new air isometric replacement is one kind of high tech product with highly effective energy conservation, the environmental protection Unit has composed: Heat-exchange system, dynamic system, control system, noise reduction system and box body Principle: The heat-exchange system uses the static-like converter to make the cold air and hot air exchange hot with highly effectiveness The dynamic system uses the low chirp air blower with highly effective to filter, to purify, to input the fresh air which is after the heat change processing, simultaneously discharges the feculent air. The filtration system may select the highly effective filter according to the design request, establishes in two gusty areas The outer covering uses the alloy skeleton, the outer wall which is made of color steel plate or the stainless steel plate, is filled with polyethylene to make it more hear preservation. Serviceability: Suits for 15-1100 square meter construction unit.
VDL Diffuser:
In terms of cooling or heating, air supply perspective can be achieved by adjusting the blades angle. Because of large scale of wind blowing, it can be suitable for industrial plants or senior activities centers, as well as public places (such as: industrial plants, airports, theaters, bank etc.)
Structure: VDL has four different specifications, positive outlets equip with adjustable blades and flow laps. The leaves can be manually adjusted, or by pneumatic device or electrical device to fulfill the task. A hydrostatic tank top or side openings are for motor control, another separate detection hole on the other side.
Main functions and features:
Fuse Action at 70'C, valves shut down automatically
Manual closed and opened, the opening angle is not adjustable
Closed signal outputs to chain-closed ventilation equipment
Specifications (L * W * H): 210 * 100 * 100 ~ 500 * 320 ** 210 mm
Structure:
Valve, bushings, control unit
Technical parameters:
Temperature sensor movements at 70'C
Refractory time: 1.5 hours
Air volume: 290 CBM / H * SM standard state
Full drag coefficient at: <0.4