IN-GD 10t20t30t50t Canister compression load cell for truck scale

FOB Price
  • US $700.00

    1 - 10 piece

  • US $650.00

    11 - 100 piece

  • US $400.00

    101 - 500 piece

  • group namecanister and compression load cell

  • Min Order1 piece

  • brand nameInntronic

  • modelIN-GD

  • payment methodL/C

  • update timeThu, 21 Feb 2019 13:48:51 GMT

Paramtents

  • Pattern Column Cylinder Type

  • Transform Type Resistance Strain

  • Out-Wire 4-Wire

  • Output Signal Type Analog Type

  • Material Stainless Steel/Alloy Steel

  • IP Rating IP68

  • Application Truck Scale

  • Capacity 10T-50T Load Cell

  • Replace Mettler Toledo Load Cell 0782GD

  • Sensitivity(Cn) / Zero Balance 2.0±0.002/0±0.02 mV/V

Packging & Delivery

  • Weight18.00kg / piece

  • Min Order1 piece

Briefing

load cell factory in China, canister compression load cell,simple to install, replace Mettler Toledo Load Cell 06782GD

Detailed

IN-GD 10T 20T 30T 50T Canister compression load cell

-----Replace Mettler Toledo Load Cell 0782GD 


- Self-restoring function;
- Nominalloads:10t-50t ;
- Simple to install;
- Laser welded, IP68;
- Optimized for parallel connection by comer pre-adjustment;
- Meets EMC/ESD requirements According to EN 45 501;


Suitable for 
Truck Scale;
Railway Scale;
Axle Wheel Scale;
Floor Scale;

Item

Unit

Parameter

Accuracy Class to OIML R60

 

C2

C3

Maximum Capacity (Emax)

t

10, 20, 30, 40, 50

Minimum LC Verification Interval (Vmin)

% of Emax

0.0200

0.0100

Sensitivity(Cn) / Zero Balance

mV/V

2.0±0.002/0±0.02

Temperature Effect on Zero Balance (TKo)

% of Cn/10K

±0.02

±0.0170

Temperature Effect on sensitivity (TKc)

% of Cn/10K

±0.02

±0.0170

Hysteresis Error (dhy)

% of Cn

±0.0270

±0.0180

Non-linearity (din)

% of Cn

±0.0250

±0.0167

Creep (dcr) Over 30 min.

% of Cn

±0.030

±0.0167

Input (RLC) & Output Resistance (Ro)

Ω

1160±10&1000±3

Nominal Range of Excitation Voltage (Bu)

V

5-12

Insulation Resistance (Ris) at 50 Vdc

≥5000

Service Temperature Range (Btu)

-30…+70

Safe Load Limit (EL) & Breaking Load (Ed)

% of Emax

150 & 200

Protection Class According to EN 60 529 (IEC 529)

 

IP68

Material: measuring element + housing

 

            Stainless or Alloy Steel        + Stainless Steel

Maximum Capacity (Emax)

t

10

20

30

40

50


Min. scale Verification (emin) according to En45 501

[...#=max. Number of Load Cells]

 

Kg

5

[6#]

5

[6#]

10

[8#]

10

[8#]

10

[6#]

20

[8#]

10

[4#]

20

[10#]

Recommended Maximum Weighing Capacity of Scale

T

30

50

80

100

100

150

100

200

Deflection at Emax (snom), approx.

Mm

0.55

0.65

0.75

0.85

0.85

Weight(G), approx.

Kg

1.9

2.1

2.3

2.5

2.7

Cable: Diameter: φ6mm Length

m

12

12

14

16

16