Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Max. Short Circuit Temp: 250°C / 5s
Tested voltage: 6.5kVAC / 5min
Rated voltage: DC 1500V U0/U=1000V
Conductor: Stranded aluminum alloy, Class 2, 1×10~400mm²
Insulation: XLPO
Cover: XLPO
Armouring: Steel tapes
Outer Sheath: XLPO
Flame test: IEC 60332-1
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -15°C~70°C
Tested voltage: 2500V AC
Rated voltage: 600V
Reference Standard: JIS C 3005, JIS C 3605
Conductor: Bare copper
Insulation: XLPE, Natural color
Jacket: PVC, Black
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: 60°C
Rated voltage: 600V
Reference Standard: JIS C 3005
Conductor: Bare copper, 0.9~100mm²
Insulation: PVC, Black, white, red, green, yellow, blue
Min Order:1000 meter
Industry:Electrical Equipment & Supplies
Rated temperature: -15°C~+90°C
Tested voltage: 14~22mm² : 2.0 k V/1min AC
Rated voltage: 600V DC
Reference Standard: JCS 4348,JIS C 3005
Conductor: Aluminum
Insulation: XLPE, Natural color
Jacket: PVC, Blue
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Tested voltage: 6500V AC
Rated voltage: 1500V DC
Conductor: Tinned copper 2X1.5~35mm²
Insulation: XLPO, Optional color
Jacket: XLPO, Optional color
Water resistance: AD8
Flammability class: Dca acc. CPR
Reference Standard: EN50618 & IEC62930
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Tested voltage: 6500V AC
Rated voltage: 1500V DC
Conductor: Tinned copper 2X1.5~35mm²
Insulation: XLPO, Optional color
Jacket: XLPO, Optional color
Water resistance: AD7
Flammability class: Cca acc. CPR
Reference Standard: EN50618 & IEC62930
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Operating Temperature: -40°C~90°C
Max. Conductor Temperature: 120°C
Tested voltage: 6kVac / 5min
Rated voltage: 450 / 750V
Conductor: Tinned copper 1.5mm²~16mm²
Insulation: XLPE
Jacket: XLPE, Color black
Flame Test: IEC60332-1
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Tested voltage: 6500V AC
Rated voltage: 1500V DC
Conductor: Tinned copper 2.5 ~ 6mm²
Insulation: XLPO, Black or white
Out Layer: XLPO, Black or red or other colors
Flame Test: VW-1/ IEC 60332-1
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Rated voltage: 600V
Conductor: Strands bare copper
Insulation: PVC, Optional color
Nylon Sheath: Nylon
Jacket: PVC, Black
Reference Standard: UL3003, UL44
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Conductor: Fine wire strands of tinned copper
Insulation: Special silicone compound
Rated temperature: -60°C ~ +150°C
Rated voltage: AC 300V
Flame Test: Horizontal flame CSA FT2
According to: UL758, UL1581
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Conductor: Tinned copper stranded, or bare copper
Insulation: Lead free PVC, Passed RoHS
Rated temperature: 105°C
Rated voltage: 600V AC
Flame test: Horizontal flame UL VW-1 & CSA FT1
According to: UL758, UL1581
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -15°C~70°C
Tested voltage: 2500V AC
Rated voltage: 600V
Reference Standard: JIS C 3005, JIS C 3605
Conductor: Bare copper
Insulation: XLPE
Jacket: PVC, Black
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Max. Short Circuit Temp: 250°C / 5s
Tested voltage: 6.5kVAC / 5min
Rated voltage: DC 1500V U0/U=1000V
Conductor: Stranded aluminum alloy, Class 5, 1×2.5~400mm²
Insulation: XLPO
Jacket: XLPO
Flame test: IEC 60332-1
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Max. Short Circuit Temp: 250°C / 5s
Tested voltage: 6.5kVAC / 5min
Rated voltage: DC 1500V U0/U=1000V
Conductor: Stranded aluminum alloy, Class 5, 1×2.5~400mm²
Insulation: XLPO
Cover: XLPO
Armouring: Steel tapes
Outer Sheath: XLPO
Flame test: IEC 60332-1
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Rated voltage: 1500V DC
Conductor: Tinned copper 1.5~240mm²
Insulation: XLPO, Black
Jacket: XLPO, Black
Related Tests: Salt mist test, Mould growth test
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Rated voltage: 600V
Insulation: XLPE, Type USE-2
Ground: Green
Conductor: Class B, Aluminum alloy
Reference Standard: UL854, UL1893
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Rated temperature: -40°C~90°C
Rated voltage: 600V
Reference Standard: UL854, UL1893
Region:JiangSu/WuXi
Port:Shanghai
Payment Method:T/T, L/C
Turnover:USD 50 - 100 million per year
Imports:Below USD 100 thousand per year
Export:USD 50 - 100 million per year
Min Order:1 piece
Industry:Electrical Equipment & Supplies
Conductor: Annealed soft tin copper
Insulation: XLPE
Rated temperature: -40°C ~ +105°C
Rated voltage: 600V AC
Flame test: Horizontal flame UL VW-1 & CSA FT1
According to: UL758, UL1581
Min Order:1 piece
Industry:Telecommunications
Region:Zhejiang/Hangzhou
Port:shanghai, Ningbo, Shenzhen, Guangzhou
Payment Method:T/T, L/C, Credit Card, PayPal, Westem Union
6YRSFCJ OPTO TECH
Turnover:USD 30 - 50 million per year
Imports:USD 5 - 7 million per year
Export:USD 10 - 12 million per year
网络文化经营许可证:浙ICP备14006100号-11 2007-2026 Tradevv.com. All rights reserved.