Screw Type Air-Cooled Chiller

  • group nameAir-Cooled Screw Chiller

  • Min Order1 piece

  • brand nameHERO-TECH

  • modelHTS-75A

  • payment methodL/C, T/T

  • update timeWed, 27 Mar 2013 20:27:27 GMT

Paramtents

  • Casing Color standard blue or other colors

  • Refrigerant R22 or R407C

  • Control method Thermostatic expansion valve

  • Evaporator Shell and Tube

  • Compressor Single Bitzer or Hanbell semi hermetic screw

  • Delivery time 20 working days

Packging & Delivery

  • Min Order1 piece

Briefing

Features of the compressors adopted by HERO-TECH screw type water chiller:
We use the new world famous brand compressors.

Detailed

Features of the compressors adopted by HERO-TECH screw type water chiller:
We use the new world famous brand compressors,such as BITZER and HANBELL.It is a new type and high-efficient screw-rotor compressor,which efficiency is 20% to 30% higher than those common ones.It has obtained several patents from countries of Europe and American and passed the international quality certification of ISO9001:2008
Technical data

Model [HTS-**

40A

50A

60A

75A

85A

100A

Item

nominal cooling capacity

kcal/h

86000

111800

129000

180600

206400

223600

kw

100

130

150

210

240

260

input power

kw

39

43

49

67

73

84

max. running current

A

91

116

122

165

215

250

power supply

3PH~380V 50HZ

refrigerant

type

R22 /R407c

refrigerating circuit

1

type of control

thermostatic expansion valve

compressor

type

semi-hermetic screw

quantity

1

start-up mode

Y- △

capacity control

0-25-50-75-100

condenser

type

air cooled type finned copper tube

evaporator

type

shell and tube

quantity

1

chilled fluid flow(m 3 /h)

17

22

26

36

41

45

safety protection

compressor over temperature, unit overload, high and low pressure, flow switch, phase sequence, phase-missing, antifreezing

net weight

kg

1600

1800

1950

2260

2500

2800

running weight

kg

1800

2000

2150

2420

2800

3100

Note: 1. nominal cooling capacity is according to:

Inlet chilled fluid temperature: 12℃.Outlet chilled fluid temperature: 7℃.

Inlet cooling air temperature: 35℃.Outlet cooling air temperature: 45℃.

2. working range:

The temperature range of chilled fluid is from 5℃ to 20℃;
Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.
The temperature difference between inlet and outlet cooling air is from 8℃ to 12℃;

Delivery clauses under the trade mode
FOB, CFR, CIF, EXW
Acceptable payment methods
T/T, L/C, Westem Union
Contact Suppliers

Follow this Suppliers