LCD intelligent PID module electric actuators HT-T series

  • group nameElectric actuators

  • Min Order1 piece

  • brand nameHeighten

  • modelHT-10T

  • payment methodT/T

  • update timeWed, 12 Jun 2013 18:11:42 GMT

Packging & Delivery

  • Min Order1 piece

Briefing

LCD display, modulating module type or PID module type, cycle life: 100,000 times, Own R&D module

Detailed

HT-T series LCD intelligent proportional electric actuator is the perfect combination of integrated PID and electric actuator. The PID controller has both a variety of functions (temperature, pressure, pressure, flow, level), but also can servo the electric actuator. It’s simple to design and install, low cost for users.
With the standard 4 ~ 20mA signal channel ,common to be access to temperature, pressure, pressure, flow, level and other sensor, calculated by PID module in the actuator, control the valve switch, feedback the sensor changes a closed regulation loop was formed.

cycle life: 100,000 times

Omron limit switch, Duty cycle: 60%

Potentiometer 0.5% linear

Own R&D module

  Two standard signal input

  Standard way signal input, the standard  way signal output

  Standard way signal input, standard output bus

Direct-mounted (ISO5211 Femail Conections) Parameters

Quartet

□9×9  □11×11   □14×14

Flange

  F05   F07

Stem

Height≤29mm

                                                                                                                    

Adapter sensor transmitter:
A: Temperature Transmitter,
B: Pressure transmitter,
C: Pressure difference transmitter,
D: Liquid level transmitter,
E: Flow Transmitter

HT-T series LCD intelligent proportional electric actuator has a user friendly interface.

                      

                                         


1, the user can set the upper and lower limit with 4 ~ 20mA sensing signal corresponding to the indicated value on the field.
2, the user can set the target operating point
3, the scene changes can adjust various parameters of PID controller in order to achieve the best conditioning effect.
4, Switch the Chinese and English menu for the use of different language areas.
5, Switch the manual and automatic function.
6, password to avoid the mistakes of non-professional.
7. optional infrared remote, convenient and comfortable. Non-invasive parameter adjustment.
8, optional bus interface, can access to equipment management system for data exchange and remote configuration.

HT-T series LCD intelligent proportional electric actuator, the adapter valve and sensor can be assembled with a closed-loop control system. Typical projects are as follows:

1. Temperature Control Valve
Temperature Transmitter T acquired the water temperature, converted into 4 ~ 20mA standard signal into the HT-T actuators. HT-T can be set the range and the target temperature. After actuator HT-T calculations, change the valve switch to control water temperature constant in the target. Temperature transmitter T, and HT-T valve actuator may form the temperature control valve. Case diagram:

2. Pressure Regulating Valve
Pressure transmitter P acquired the pressure after the valve, and then converted into 4 ~ 20mA standard signal into the HT-T actuators. HT-T actuator can set the range and the target pressure value. After actuator HT-T calculations, change the valve switch, the control valve pressure constant in the target. Pressure transmitter P, and the HT-T valve actuator pressure regulating valve can be formed. Case diagram:

3. Pressure Differential Regulating Valve
Pressure transmitter P1, P2 were used to acquired the pressure value before and after the valve, and then converted into 4 ~ 20mA standard signal into the HT-T actuators. HT-T actuator can be set the range and the target values. After actuator HT-T calculations, change the valve switch adjustment to control the pressure constant in the target line. Pressure transmitter P1/P2, and HT-T valve actuator pressure regulating valve can be formed. Case diagram:

4. Level Control Valve
Water level transmitter W acquired the level value, converted into 4 ~ 20mA standard signal into the HT-T actuators. HT-T actuator can be set the range the target level value. After actuator HT-T calculations, change the valve switch to control water level constant in the target. Level Transmitter W, valves, and HT-T can form liquid level actuator control valve. Case diagram:

5. Flow Control Valve
Flow of electromagnetic flow meter acquired the flow value, then converted into 4 ~ 20mA standard signal into the HT-T actuators. HT-T actuator can be set the range and the target value. After actuator HT-T calculations, change the valve switch to control the flow of a constant in the target line. Electromagnetic flow meter (or other types of electronic flow meter), and HT-T valve actuator flow control valve can be formed. Case diagram:

Specification

Power Supply

Model

HT-10T

DC24V

AC24V

AC110V

AC220V

AC380V

Power

30W

30W

30W

30W

20W

Rated Current

2.53A

2.62A

1.07A

0.80A

0.60A

Output Torque

100Nm

50/100Nm

100Nm

90° Operational Time

30S

15S/30S

30S

Operational Angle Range

Adjustable from 0 to 360°

Adapter Control Circuit

T Series: proportional type

Weight All

4.5kg

Insulation Resistance

DC24V/AC24V:100MΏ/250VDC  AC110V/AC220V/AC380V:100MΏ/500VDC

Withstand Voltage

DC24V/AC24V:500VAC per minute,  AC110V/AC220V:1500VAC per minute,  AC380V:1800VAC per minute

Enclosure Rating

IP65

Mounting Direction

360° installed at any angle

Electric Conduit

M20 waterproof cable connector

Ambient Temperature

-30℃ ~ +60℃

Various Option

Fast turn-off, over torque protection, dehumidification heaters

              

Nearest port for product export
Shanghai port
Delivery clauses under the trade mode
FOB, CFR, CIF
Acceptable payment methods
T/T, Westem Union