Two-way/ three way Control Valve

  • group nameHVAC Balancing Valve

  • Min Order1 set

  • modelSRV series

  • payment methodT/T

  • update timeThu, 13 Jul 2017 10:27:22 GMT

Paramtents

  • Material Ductile iron

  • Size DN15~DN400

  • Medium water/ ethylene glycol, steam

  • Connection Flange connection

  • Function two/ three way control

  • Control equal percentage

Packging & Delivery

  • Min Order1 set

Briefing

Material: Ductile iron
DN32~DN200
PN16
Hydraulic valve

Detailed

Application:

The two-way valve (a three-way valve may also be used) is installed in heating and cooling systems

with a closed water circuit (e.g. central heating systems, fan coil units, chilled ceilings or fan convectors)

and serves the flow volume and temperature control in combination with actuators and thermostats.

When used as a three-way valve, it is for mixing or distributing the volume flows in bivalent heating

systems or hot water storage cylinders, for instance in solar or heat pump installations.


Material:


Valve body made of Ductile Iron, disc and stem made of Stainless steel, Seal ring made of Teflon.


Function:


When used as a two-way valve, the SUNFLU two-/three-way valve has one inlet port (A) and one outlet 

port (AB).


If the stem is pressed down, the straight port (AAB) is opened.


The central nipple is closed with a blind flange. The valve can be used as three-way valve after removal 

of the blind flange.


When used as a three-way mixing valve, the valve has two inlet ports (A and B) and one outlet port 

(AB).


Depending on the position of the valve disc, the cold and hot water is mixed. If the stem is pressed 

down, the inlet port A is opened and the inlet port B is closed.


When used as a three-way diverting valve, the valve has one inlet port (AB) and two outlet ports (A and 

B).


Depending on the position of the valve disc, the direction of flow is diverted from one to the other outlet 

port.




Technical data:

Permissible Pressure: PN16

Standard of flanged connection: ISO 7005-2

Leakage rate: 0.002% of Kvs

Permissible Media: Chilled water, cooling water, Anti-freeze water, Refrigerant, (R12、 R22、R134a、

R202)

Glycol, Hydrazine, Phosphate, Low and high temperature hot water, Saturated 

steam(≤130℃or≤0.1MPa)

Temperature: -10-130℃

Stroke: 20mm (DN40~DN65),  30mm (DN80), 40mm (DN100~DN150)


Dimension:




1. Valve


DN

Kvs

(m³∕h)

Piston

stroke

Actuator

ΔPs

(Mpa)

Work Pressure

Liquid Temperature

Cooling

Heating

32

16

20

SACRV1000

SACRV1800

≤1.6

16bar

0-130℃

40

25

20

50

40

20

65

63

20

SACRV1500

80

100

30

100

160

40

SACRV3000

125

250

40

150

350

40

200

520

40


2. Electric Actuator


Model

Force

Operating

voltage

Control

signal

Environment Temperature

Protection Degree

SACRV1000

1000N

24VAC/220VAC

3-position OR

0-10V 2-10V

0-20mA 4-20mA

0-60℃

IP54

SACRV1500

1500N

24VAC/220VAC

SACRV1800

1800N

24VAC/220VAC

SACRV3000

3000N

24VAC/220VAC


3. Size


DN

L

D

D1

nXd

H1

H2

Two-way

H2’

Three-way

32

180

140

100

4X19

50

80

121

40

200

150

110

4X19

50

82

122

50

230

165

125

4X19

60

98

136

65

290

185

145

4X19

90

112

156

80

310

200

160

8X19

120

130

185

100

350

220

180

8X19

136

150

202

125

400

250

210

8X19

157

175

240

150

480

285

240

8X23

171

200

270

200

500

340

295

12X23

185

238

315