group nameReliable Test Chamber
Min Order1 piece
brand nameHUDA Test Machine Manufacturer
modelHUD-E714
payment methodT/T, L/C, D/P D/A, Cash
update timeFri, 10 Sep 2021 10:54:35 GMT
Internal dimension (W*D*H) 1000*1000*1000mm
Temperature range 70~+100℃(no load);-55~+100℃(with load)
Temperature fluctuation ±0.5℃
Temperature uniformity ±2℃
Ambient Humidity ≤85%RH
Cooling speed ≥1℃/min in average (with loading 15kg,+85℃~-55℃ )
Heating speed 1℃/min in average (with loading,-55℃~+85℃)
Min Order1 piece
Low pressure test chamber is mainly used in aviation, aerospace, information, electronics and other fields, instruments and meters, electric products, materials, parts, equipment at the same time in the low pressure, high temperature, low temperature single or under the action of the environmental adaptability and reliability of the test, and or electric performance parameters for the specimen electricity measurement, adopt and composite structure form, the test chamber by is located in the front of the heat preservation box (confined structure), located at the back of the refrigeration, located on the chamber door vacuum unit and the electrical controller (system)
1. High performance and quiet operation
2. Space-saving designed for flush installation to wall
3. External pressure type box body structure and stainless steel tank design, rational air circulation system and scientific layout of heating, refrigerating system
4. Adopts international brand of imported parts for cooling system to improve operation reliability
5. High precision and stable performance with touch screen controller, friendly Man-Machine interface.
6. Multiple layers of safety device to easy maintenance.
Internal dimension (W*D*H) | 1000*1000*1000mm |
Temperature range | -70~+100℃(no load);-55~+100℃(with load) |
Temperature fluctuation | ±0.5℃ |
Temperature uniformity | ±2℃ |
Ambient Humidity | ≤85%RH |
Cooling speed | ≥1℃/min in average (with loading 15kg,+85℃~-55℃ ) |
Heating speed | 1℃/min in average (with loading,-55℃~+85℃) |
Pressure Range | 101Kpa~1Kpa |
Pressure Accuracy | ±5% |
Pressure Control Method | Adjust temperature first, then pump vacuum |
Internal chamber material | Steel plate with plastic spray |
External chamber material | Stainless steel |
Cooling method | Water Cooler |
Controller | LCD touch screen, programmable control temperature and Pressure Can set different parameter for cyclic test |
Insulation material | Compound material without sweating, special for low pressure |
Heating Method | Electrical |
Compressor | Imported new generation with low noise |
Safety protection device | Protection for leakage Over-temperature Compressor over voltage and overload Heater short circuit |