ISP4MC3 0.3 0.5 2 3kg Single Point Load Cell for electronic balance

  • group nameSingle Point Load Cell

  • Min Order1 piece

  • brand nameInntronic

  • modelISP4MC3

  • payment methodL/C

  • update timeThu, 22 Mar 2018 21:26:06 GMT

Paramtents

  • Type Single Point Load Cell

  • Material Aluminum load cell

  • Capacity 0.3 0.5 2 3kg

  • Sensitivity 1.0±0.1 2.0±0.2

  • Accuracy C3

  • Zero balance 0±0.1

  • Application electronic balance

  • IP Rating IP67

  • Hysteresis error (dhy)3) ±0.0150

  • Non-linearity (dlin)3) ±0.0150

Packging & Delivery

  • Weight1.00kg / piece

  • Min Order1 piece

Briefing

load cell factory in China,Single Point Load Cell,Analog Load Cell,Aluminum Load Cell

Detailed

ISP4MC3 0.3 0.5 2 3kg Single Point Load Cell 
for determining small masses


Special features

For determining small masses

Small size

Accuracy class C3 with OIML-

R60 test report

Off center load compensated

Degree of protection IP65

according to IEC 529

Shielded connection cable











Type

IPW4MC3

Order-No.

1-PW4C3/300G-1

1-PW4C3/500G-1

1-PW4C3/2KG-1

1-PW4C3/3KG-1

Accuracy class1)

C3

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

g/kg

300

500

2

3

Minimum LC verification interval (vmin)

g

0.05

0.1

0.2

0.5

Temperature effect on

zero balance (TK0)

% v.

Cn /

10 K

 

0.0233

0.0280

0.0140

0.0233

Max. platform size

mm

800 x 800

Sensitivity (Cn)

mV/V

1.0±0.1

2.0±0.2

Zero balance

 

0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

% of Cn

±0.0175

±0.0117

Hysteresis error (dhy)3)

±0.0150

Non-linearity (dlin)3)

 

±0.0150

Minimum dead load output return (DR)

 

Ω

±0.0245

Off center load error4)

±0.0233

Input resistance (RLC)

380±38

Output resistance (R0)

380±38

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

15

Insulation resistance (Ris) at 100 VDC

 

> 2

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

load limit (EL )

 at max.

100mm eccentricity

% of

Emax

% of

Emax

150

100

Lateral load limit (Elq), static

200

Breaking load (Ed)

 

300

Deflection at Emax (snom), approx.

mm

kg

< 0.4

Weight (G), approx.

0.07

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

                                              PVC