Paramtents

  • Type Single Point Load Cell

  • Material Aluminum load cell

  • Capacity 7.2kg to 72kg

  • Sensitivity 2.2±0.2

  • Accuracy C3, C3MR

  • Input impedance 300 ... 500

  • Output impedance 300 ... 500

  • Zero balance 0±0.1

  • Application static weighing

  • IP Rating IP67

Packging & Delivery

  • Weight1.00kg / piece

  • Min Order1 piece

Briefing

load cell factory in China,Single Point Load Cell,Analog Load Cell,Aluminum Load Cell

Detailed

IPW2C 7.2kg to 72kg Single Point Load Cell 
for static weighing



Special features

− Accuracy class C3/C3MR and C6/C6MR with OIML-R60 test report

− Max. capacities: 7.2 kg ... 72 kg

− Off center load compensated(OIML R76)

− Degree of protection IP67(according to EN 60 529)

− Shielded connection cable

− optimized for dynamic weighing applications

Optional:

- Different accuracy classes with OIML-R60 test report

− Connection cable in six wire circuit

− Different cable lengths

− Aligned output, suitable for

Aligned output, suitable for connectionin parallel


Type

IPW2C

Accuracy class1)

C3; C3MR

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

7.2

12

18

36

72

 

Minimum LC verification interval (vmin)

Accuracy class C3

g

1

2

5

10

20

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0194

±0.0233

±0.0389

±0.0389

±0.0389

Minimum LC verification interval (vmin)

Accuracy class C3MR

g

0.5

1

2

5

10

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K

 

±0.0097

±0.0116

±0.0155

±0.00194

±0.0194

Max. platform size

mm

380 x 380

Sensitivity (Cn)

mV/V

2.2±0.2

Zero balance

0±0.12

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0166

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

300 ... 500

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1 ... 12

Insulation resistance (Ris) at 100 VDC

> 2

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

160

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Weight (G), approx.

kg

0.25

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

PVC