IN-SQBKC 0.25t to 5t Double beam Load Cell for Tank scale

  • group nameDouble Beam Load Cell

  • Min Order1 piece

  • brand nameInntronic

  • modelIN-SQBKC

  • payment methodL/C, T/T

  • update timeFri, 03 Nov 2017 16:29:19 GMT

Paramtents

  • Brand Innovation

  • Delivery Time 5-8 work days

  • Application Tank scale

  • Capacity 0.25t to 5t

  • IP Rating IP67(0.25~0.5t);IP68(1t~5t)

  • Creep error(30minutes) ±0.03% F.S

  • Zero balance ±1% F.S

  • Material alloy steel/stainless steel

  • Rated output 2.0±0.002mv/v

  • Hysteresis error ±0.02% F.S

Packging & Delivery

  • Min Order1 piece

Briefing

load cell factory in China, Double Beam Load Cell,Arc force loading,Low profile,alloy steel, stainless steel

Detailed

IN-SQBKC 0.25t to 5t Double beam Load Cell

 for Tank scale

Product Details

FEATURES:

Capacity: 0.25t to 5t

Arc force loading

Low profile

Material Option: alloy steel, stainless steel

APPLICATION:

Tank scale

Outline Dimension

Rated capacity(t)

L

L1

L2

L3

W

W1

W2

H

C1

C2

C3

RF

0.250.51, 22.5

130

76.2

25.4

15.8

31.8

15.8

6

31.8

Φ13.5

Φ15.2

Φ23.4

11.2

3,5

171.5

95.3

38.5

19

38

22.9

5.5

38

Φ20

Φ21.8

Φ30.5

14.2

 

SPECIFICATION:

Rated capacity: 0.25ton to 5ton

Operating temperature range: -30 to +70

Rated output:2.0±0.002mv/v

Maximum safe overload150% OF R.C

Combined error±0.05% F.S

Ultimate safe overload180% OF R.C

Non-repeatability±0.02% F.S

Recommended Excitation10 to 12V DC

Non-linearity±0.05% F.S

Maximum Excitation15V DC

Hysteresis error±0.02% F.S

Environment protection: IP670.25~0.5t);IP681t~5t

Zero balance: ±1% F.S

Input impedance: 400±20Ω

Creep error(30minutes): ±0.03% F.S

Output impedance: 352±3Ω

Temperature effect on zero: ±0.02% F.S

Insulation resistance at 50V DC: ≥5000MΩ

Temperature effect on output: ±0.02% F.S

Material: Alloy steelStainless steel

Compensated temperature range: -10 to +40

Cable length: 5 meter, diameter 5.1mm