Full Digital Conversion Load Cell Transmitter Analog Output Two - Button Calibration

  • group nameWeighing Controller and indicator

  • Min Order1 piece

  • brand nameInntronic

  • modelINA2PS

  • payment method

  • update timeWed, 15 Aug 2018 11:40:56 GMT

Paramtents

  • accuracy 1/10000

  • Non-linearity ≤0.008%F.S

  • Zero te℃mperature drift ≤0.4μV/℃

  • Temperature coefficient of span ≤10ppm/℃

  • Net input range of full capacity -30 mV ~ +30mV

  • Sensitivity of analog input signal 0.5uV /d (Min.)1.5uV/d (Recommend)

  • Calibration range +- 50%FS

  • Output optional 0~5V,0~10V,4~20mA(DIP switch selection)

Packging & Delivery

  • Min Order1 piece

Briefing

Full Digital Conversion Load Cell Transmitter Analog Output Two - Button Calibration

Detailed

INA2PS 0-10V 4-20MA weight transmitter amplifier for batching scale silo scale Net input range of full capacity: -30 mV ~ +30mV



  • This Load cell amplifier/Weight transmitter Built-in 24 bits Σ-Δ integrated ADC chip for weighing conversion;
  • Full digital conversion, no potentiometer or any other analog conditioning components;
  • Analog output two-button calibration, it only needs calibrate once of zero and full.


1.  Accuracy: 1/10000
2 . Non-linearity: ≤0.008%F.S
3 . Zero temperature drift: ≤0.4μV/℃
4 . Temperature coefficient of span: ≤10ppm/℃
5 . Net input range of full capacity: -30 mV ~ +30mV
6 . Sensitivity of analog input signal: 0.5uV /d (Min.)
     1.5uV/d (Recommend)
7. Calibration range: +- 50%FS
8 . Display: No display
9 . Working temperature: -30℃~ 60℃
10 . Relative humidity: ≤ 90%(No condensation)
11 . Power supply: +18 ~ +26VDC,>0.5A
12. Load cell bridge voltage: DC 5V 1.5A Can max connect with 8 pieces of load cells whose impedance > 350Ω
13 . Output optional: 0~5V,0~10V,4~20mA(DIP switch selection)



Load cell amplifier/Weight transmitter Wiring:



  •  +E: load cell power supply +
  •  -E: load cell power supply -
  •  GND: shield
  •  +S: feedback signal +
  •  -S: Feedback signal -