YOKOGAWA EJA110E-FMS5C-917DB/KS26/D3/M01 4 to 20 mA liquid gas steam Pressure Transmitter

FOB Price
  • US $650.00

    1 - 1 piece

  • US $410.00

    2 - 10 piece

  • group namePressure transmitter

  • Min Order1 piece

  • brand nameShelok

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeMon, 17 Sep 2018 11:57:48 GMT

Packging & Delivery

  • Min Order1 piece

Briefing

EJA110E can measure liquid, gas, or steam flow as well as liquid level, density and pressure.

Detailed

The high performance differential pressure transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure. EJA110E outputs a 4 to 20 mA DC signal corresponding to the measured differential pressure. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.Total Probable Error (M capsule) ±0.20% of Span @1:1 to 5:1 Rangedown Total probable error, known as a measure of the total performance of the transmitters under the condition of fixed line presurre. Total Probable Error = ± E12 + E22 + E32 E1: Reference Accuracy of Calibrated Span E2: Ambient Temperature Effects per 28°C change E3: Static Span Effects per 6.9 MPa change ? Total Accuracy (M capsule) ±0.17% of Span @1:1 Rangedown ±0.33% of Span @ 5:1 Rangedown Total accuracy is a comprehensive measure of transmitter total performance, covering all major factors in actual installation, that cause errors in measurement. As a standard measure, YOKOGAWA uses this to evaluate transmitter performance. Total Accuracy = ± E12 + E22 + (E3 + E4)2 + E52 E1: Reference Accuracy of Calibrated Span E2: Ambient Temperature Effects per 28°C change E3: Static Span Effects per 6.9 MPa change E4: Static Zero Effects per 6.9 MPa change E5: Overpressure Effects upto overpressure 16MPa Not only a day-to-day changes in temperature can affect the measurement and lead to unnoticed errors; fluctuaion of line pressure, incorrect operation of three/five valve manifold leading to over-pressure events, and other phenomena can have the similar result. Total Accuracy factors in such changes and errors and provides much comprehensive and practical determination of how a transmitter will perform under actual plant operation.Overpressure Effects Overpressure condition: up to maximum working pressure M, H and V capsules, except for gold-plated diaphragm. ±0.03% of URL Stability (All normal operating condition, including overpressure effects) M, H and V capsules ±0.1% of URL per 10 years F capsule ±0.2% of URL per one year Power Supply Effects(Output signal code D and J) ±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω) Vibration Effects Amplifier housing code 1 and 3: Less than 0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz, 0.21 mm displacement/60-2000 Hz 3 g) Amplifier housing code 2: Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15mm displacement /60-500 Hz 2g) Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.4 kPa (1.6 inH2O) which can be corrected by the zero adjustment. Response Time (Differential pressure) 90 ms for Wetted Parts material code S and L, except for Measurement span code F. 150 ms for Wetted Parts Material Code H, M, T, A, B, D and W or Measurement span code F. When amplifier damping is set to zero and including dead time of 45 ms (nominal)Static Pressure Signal Range and Accuracy (For monitoring via communication or on indicator. Includes terminal-based linearity, hysteresis, and repeatability) Range Upper Range Value and Lower Range Value of the static pressure can be set in the range between 0 and Maximum Working Pressure(MWP). The upper range value must be greater than the lower range value. Minimum setting span is 0.5 MPa(73 psi). Measuring either the pressure of high pressure side or low pressure side is user-selectable. Accuracy Absolute Pressure 1 MPa or higher: ±0.5% of span Less than 1 MPa: ±0.5%×(1 MPa/span) of span Gauge Pressure Reference Gauge pressure reference is 1013 hPa (1 atm) Note: Gauge pressure variable is based on the above fixed reference and thus subject to be affected by the change of atomospheric pressure. □ FUNCTIONAL SPECIFICATIONS Output For 4 to 20 mA HART / BRAIN (Output signal code D and J) Two wire 4 to 20 mA DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol are superimposed on the 4 to 20 mA signal. Output range: 3.6 mA to 21.6 mA Output limits conforming to NAMUR NE43 can be pre-set by option code C2 or C3. For 1 to 5 V HART (Output signal code Q) Three or four wire low power 1 to 5 V DC output with HART, linear or square root programmable. HART protocol are superimposed on the 1 to 5 V DC signal. Output range: 0.9 V to 5.4 V DC Failure Alarm For 4 to 20 mA HART / BRAIN (Output signal code D and J) Analog output status at CPU failure and hardware error; Up-scale: 110%, 21.6 mA DC or more (standard) Down-scale: ?5%, 3.2 mA DC or less For 1 to 5 V HART (Output signal code Q) Analog output status at CPU failure and hardware error; Up-scale: 110%, 5.4 V DC or more (standard) Down-scale: ?5%, 0.8 V DC or less Damping Time Constant (1st order) Amplifier damping time constant is adjustable from 0.00 to 100.00 s by software and added to response time. Note: For BRAIN protocol type, when amplifier software damping is set to less than 0.5 s, communication may occasionally be unavailble during the operation, especially while output changes dynamically. The default setting of damping ensures stable communication. Update Period Differential pressure: 45 ms Static pressure: 360 msZero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the digital indicator with rangesetting switch. Integral Indicator (LCD display, optional) 5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to four of the following variables periodically.; Measured differential pressure, differential pressure in %, scaled differential pressure, measured static pressure. See also “Factory Setting.” Local Parameter Setting (Output signal code D, J and Q) Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters of Tag number, Unit, LRV, URV, Damping, Output mode (linear/square root), Display out 1, and Re-range by applying actual pressure (LRV/URV). Burst Pressure Limits 69 MPa (10,000 psi) for wetted parts material S, except for Measurement span F. 47 MPa (6,800 psi) for wetted parts material other than S or Measurement span F. Self Diagnostics CPU failure, hardware failure, configuration error, and over-range error for differential pressure, static pressure and capsule temperature. User-configurable process high/low alarm for differential pressure and static pressure is also available. Signal Characterizer (Output signal code D, J and Q) User-configurable 10-segment signal characterizer for 4 to 20 mA output. SIL Certification EJA-E series transmitters except Fieldbus, PROFIBUS PA and 1-5V DC with HART (Low Power) communication types are certified in compliance with the following standards; IEC 61508: 2010; Part1 to Part 7 Functional Safety of Electrical/electronic/ programmable electronic related systems; SIL 2 capability for single transmitter use, SIL 3 capability for dual transmitter use. NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits ?40 to 85°C (?40 to 185°F) ?30 to 80°C (?22 to 176°F) with LCD display Process Temperature Limits ?40 to 120°C (?40 to 248°F) Ambient Humidity Limits 0 to 100% RH Working Pressure Limits (Silicone oil) Maximum Pressure Limits (MWP) 16 MPa (2300 psi) 25 MPa (3600 psi) for option code /HG