HHO Browns Gas Generator kit hydrogen engine carbon cleaner for combustion chamber

  • group nameEngine Carbon Cleaning Machine

  • Min Order1 set

  • brand nameZeayeto

  • modelHHO-1500

  • payment methodL/C, D/A, D/P, Western Union

  • update timeWed, 20 Nov 2019 14:23:57 GMT

Paramtents

  • Gas production 2000 L/H±10%

  • Working pressure ≤0.020bar

  • Ambient temperature range 5℃~50℃

  • Altitude range-sea level to 2400m

  • Frequency 50/60HZ

  • Power <6 KW

Packging & Delivery

  • Size110cm x 60cm x 60cm

  • Weight200.00kg / set

  • Min Order1 set

Briefing

hydrogen and oxygen combustion to remove the engine carbon, product is water,no pollution and easy to operate.

Detailed

HHO Browns Gas Generator kit hydrogen engine carbon cleaner for combustion chamber


HHO characteristics: 

1. Using pure water and electrolytes to produce Hydrogen and Oxygen.

2. The gas enter the engine system through pipelines.

3. Cleaning carbon only needs 20 minutes.

4. Through removing the engine carbon deposit to decrease the fuel consumption.

5. Finally the carbon becomes CO2 and H2O draining the exhaust pipe.

6. No need to dismantle engines parts

7. No harm to engine, human and environment

8. Much cost saving than the other machine.

 


Technical data:

Model Number

HO-1500

AC Voltage Requirement (V)

220~240V,single phase

AC Current (A)

<15

Rated Power(KW)

4.5

Max. Gas Output(L/h)

1500

Max. Working Pressure (Mpa)

0.02

Max. Water Consumption (L/h)

0.7

Weight (kg)

120

Dimensions - L*W*H (mm)

600*650*1250


 

Effects of carbon cleaning

1. Reduce oil consumption

2. Reduce engine noise

3. Save car repairing cost

4. Prolong engine life

5. Increase 20% of engine power

6. Decrease 70% of air pollution

 

Causes of carbon cleaning failure

No.

Fault phenomenon

Cause Analysis

Method of exclusion

1

The machine does not work when the start button is pressed

Missing phase, carbon removal control board failure or air switch damage or emergency stop button has been pressed

1)1) Check the power supply

2)2) Replace the faulty device

3)Detect emergency stop button

2

When the equipment is working, the gas production is too low to meet the requirements for use.

The electrolyte concentration is too low, the electrolytic cell is too dirty, and the electrolyte is not clean.

Cleaning the electrolytic cell, descaling, replacing the electrolyte

3

Over pressure alarm

Equipment line blockage

Check equipment piping

4

Normal air pressure, low air output

Equipment piping leaks

Check equipment piping to find leaks and recover

5

Work indicator does not light after booting

The power module or power cable is not connected properly.

Check the line, replace the power module, and replace the power cord