Medical Device Infant Radiant Warmer for Newborn

  • group nameInfant Incubator

  • Min Order1 piece

  • modelCNME010717

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeThu, 29 Jul 2021 14:33:24 GMT

Paramtents

  • Type Infant Radiant Warmer

  • Function Warmer

  • Theory Electrotherapeutics

  • Certification CE

  • Control Mode Pre-Warm Mode, Manual Mode and Baby Mode

  • Standard Configuration WarmerModule, Bassinet, Main Column, etc

Packging & Delivery

  • Min Order1 piece

Briefing

Medical Device Infant Radiant Warmer for Newborn ,Manual Mode and Baby Mode control by micro-computer .

Detailed

Medical Device Infant Radiant Warmer for Newborn

Basic Info.
Model NO.
CNME010717
Optional Configuration
Disposable Skin Temperature Sensor, SpO2, etc
Operating Environmental Range
18°c~30°c
Baby Mode Temperature Control Range
34.5°c-37.5°c
Skin Temperature Display Range
5°c-65°c
Accuracy of Skin Temperature Sensor
±0.2°c
Temperature Uniformity of Mattress
≤2°c
Failure Alarm
Over Temperature Alarm, Deviation Alarm, etc
Specification
Dimension: 1270*810* 1120mm
Origin
China
Medical Device Infant Radiant Warmer for Newborn
Brief Introduction:
Three control Modes: Pre-warm Mode,Manual Mode and Baby Mode control by micro-computer;
Set Temperature and Baby Temperature can be displayed separately;
Horizontal angle of warmer module and inclination of the bassinet can be adjusted;
The panels surrounded bassinet can be turned outward or disassembled;
X-ray cassette under the bassinet;
APGAR timer;
Multiple failure alarm indications;
RS232 connector for data output.
Optional Configuration:
Disposable skin temperature sensor, Vertical height adjustment (VHA) stand, Weighing system and SpO2.
Standard Configuration:
CNME010717: 
Warmer module, bassinet, main column, mobile stand, controller, I.V. Pole and tray.
CNME010717B:
Based on CNME010717, plus the phototherapy unit.
CNME010717A:
Based on CNME010717B, plus the breath resuscitation bag; infant head fixing unit, the oxygen supplying set ( the oxygen cylinders, buoy type oxygen regulator, wall type oxygen regulator), low-pressure suction.

Environmental Requirement:
Operating range: 18°C~30°C
Ambient air velocity rate: <0.3 m/s
Medical Device Infant Radiant Warmer for Newborn Product Packaging:
Package: The whole unit is packed into one carton
Dimension: 1270mm X 810mm X 1120mm
Gross Weight: 110kg(CNME010717)
120kg(CNME010717B)
142kg(CNME010717A)
Specification:
Product name
Medical Device Infant Radiant Warmer for Newborn
Power requirement
AC220V-230V/50Hz or AC110-120V/50-60Hz, 700VA (CNME010717)
AC220V- 230V/50Hz or AC110-120V/50-60Hz, 750VA (CNME010717B/CNME010717A)
Control Mode
Pre-warm Mode, Manual Mode and Baby Mode are controlled by micro-computer
Baby Mode temperature control range
34.5°C-37.5°C
Skin temperature display range
5°C-65°C
Accuracy of skin temperature sensor
±0.2°C
Temperature uniformity of mattress
≤2°C
Angle of heater head
0° , 30° , 60° , 90° for two ways
Inclination of the bassinet
±10°
APGAR timer
audible and visible alarm when the device runs to 50"~1',4'50"~5',9'50"~10'
Failure alarm
over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
The total irradiance Ebi on the effective surface area
≥0.66mW/cm2 (CNME010717B/CNME010717A)
Average value of general bilirubin radiation on the mattress effective range
≥0.58mW/cm2 ( CNME010717B/CNME010717A)
Bilirubin uniformity of radiating on the mattress effective range
>0.4 (CNME010717B/CNME010717A)
Dominant wavelength of blue light
420-470nm
Hospital Equipment Neonatal Care Infant Incubator with the side door Product Packaging:
Packing: The whole unit is packed into one carton
Dimension: 1085mm x 640mm x 1120mm
Gross Weight: 72Kg
More Options for your selection