Diabetes,Neuropathy testing device,Diabetic Monofilament Pen

  • group nameBlood flow detector and Infrared Therapy

  • Min Order10 piece

  • modelTesting Pen1

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeFri, 07 Jan 2022 14:28:44 GMT

Paramtents

  • Power Source Manual

  • Power Supply Mode Removable Battery

  • Material Plastic

  • Quality Certification ce

  • Instrument classification Class II

Packging & Delivery

  • Min Order10 piece

Briefing

Neuropathy testing pen can be used forassessing precise the sensation of peripheral neuropathy parts of diabetic patient.

Detailed

Diabetes,Neuropathy testing device,Diabetic Monofilament Pen
Quick Details
Model Number
Testing Pen1
Origin
Tianjin, China
Power Source
Manual
Power Supply Mode
Removable Battery
Material
Plastic
Instrument classification
Class II
Quality Certification
ce
Safety standard
GB/T18830-2009
Type
Reflector Apparatus
Clinical Application
Testing Instrument of Neuropathy
Treatment
High risk foot disease screening
Manufacturer
Production certificate
Certificate
CE and ISO13485
Diagnostic
Diabetic foot diagnostic pen
Diagnostic tool
Diagnostic test kits diabetics
Diabetic Monofilament Pen

Neuropathy testing pen can be used forassessing precise the sensation of peripheral neuropathy parts of diabetic patient, so that the doctor according to the assess results, to implement effective treatment for patients with diabetic and the patient of peripheral neuropathy.
Clinical Application
Monofilament-Easy to testing touch sensation of diabetic or patient of peripheral neuropathy .
Neuro tip-Assessing precisely the sharpness sensation of peripheral neuropathy parts of patients.
Components
1.Barrel, cap, pocket clip
2.include: buttons, monofilament, slot;
3.The part of testing sharpness sensation of Neuro- Testing Pen include: pin, neurotip pressure gauge, 40g marker

Basic parameter 
Size:123mm×16.7mm×12.4mm, error is ±10%.
Weight:10g,error is±10%.
Instruction
 (1). Monofilament Test (Test of touch sensation)
1.Fully extend the monofilament slowly by sliding the button to the end of Neuro- Testing Pen until it is firmed in the end of slot.
2.Prepare the patient for test, hold the monofilament in position for 1-2 seconds before removing, and the monofilament is calibrated to bend at 10g of force. Then observe and ask the patient feeling situation, If there is no touch sensation, it is verified the patient loss of sensation in this position.
3.Monofilaments lose will lose their accuracy if used regularly after 100uses. The workers should be replace the monofilament or Neuropathy Testing Pen, they can also contact directly manufacturer or distributor.
(2).Neurotip test (Assessing sharpness sensation)
1.Take off the cap, make use alcohol wipe to clean the neurotip.
2.Put the sterile neurotip on neuropathic parts of patients, press the neurotip until the button of press gauge arrive 40g marker, then ask the patient whether if they have sharpness pain, if they have any sensation, it is verified they have loss sensation serious in this part.
Maintenance
1. Before and after using Neuropathy Testing Pen, they should clean monofilament and neurotip with alcohol wipe or antiseptic solution.
2. After clean NeuropathyTesting Pen, adjust monofilament back to the original location to slip to the top of the slot , and cap on neurotip.