LCA 2 Series Max Detection Distance 12 m Beam Spacing 500 / 400 / 300 mm Light Grid Replacement

  • group nameLCA 2 Series Safety Light Curtain Replacement

  • Min Order1 piece

  • brand nameDADISICK

  • modelLCA 2 Series | LCA-2TR-2B-510, LCA-2TR-3B-810, LCA-2TR-4B-910

  • payment methodT/T

  • update timeFri, 10 May 2024 11:20:38 GMT

Paramtents

  • Series: LCA 2 Series

  • Resolution: 2/3/4 Beams

  • Scanning range: 12 m

  • Protective field height: 510 mm / 810 mm / 910 mm

  • 2 Safety outputs (OSSD): 2 PNP

  • Response time: 3 ms - 3.5 ms

  • Connection type: M12

  • Security level PLe2

Packging & Delivery

  • Min Order1 piece

Briefing

DADISICK is a professional manufacturer of safety sensors with solid product manufacturing capabilities.

Detailed

LCA 2 Series Safety Light Grid Replacement Parameter
Brand
From network
DADISICK
Models
LCA-2TR-2B-510
LCA-2TR-3B-810
LCA-2TR-4B-910
Beam spacing
500 mm, 400 mm, 300 mm
200 mm, 80 mm
Protected altitude
510 mm, 810 mm, 910 mm
600 mm, 880 mm
Scanning range
12 m
0.3 m - 15 m
Response time
3 ms - 3.5 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65 / IP67
IP65
Connector
M12
M16
Housing cross-section
28 mm × 30 mm
35 mm × 51 mm
Safety Certificate
TÜV, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT04-200-600-2BD, QT12-80-880-2BD, QT12-80-880-2BD

FAQ
What is the significance of installing area protection safety grids?

A zone safety light curtain is a type of safety device that uses invisible beams, such as infrared or laser beams, to monitor whether there are people or objects entering a hazardous area. Its purpose is to protect personnel and equipment. Without such safety measures in place, people and equipment in hazardous areas may be at risk of serious injury or even death. Installing zone safety light curtains can effectively prevent such incidents from occurring. Therefore, it is crucial to install zone safety light curtains in hazardous areas.

In addition, area protection safety grids can also help businesses comply with relevant safety regulations and standards, such as the Occupational Safety and Health Administration (OSHA) standards in the United States. These regulations and standards require companies to take necessary measures to ensure the safety of employees and the public, and to prevent accidents from occurring. Therefore, installing area protection safety grids in hazardous areas is also a demonstration of a company fulfilling its social responsibility.

In summary, the DADISCHER QSA series of area protection safety grids not only effectively protect the safety of personnel and equipment but also help businesses comply with relevant regulations and standards, fulfilling their social responsibility.

Area protection safety grids can be classified into single-sided, double-sided, and three-sided, primarily based on the direction of beam transmission.

Single-sided grids are typically suitable for scenarios where only one side needs protection, such as robot operation areas, conveyor belts, and automated assembly lines.

Double-sided grids are applicable to scenarios where both sides need protection, such as bidirectional conveyor belts and bidirectional assembly lines.

Three-sided grids are used in scenarios where three sides need protection, such as rotating equipment, material elevators, and three-dimensional shelves.

In practical applications, it is important to choose the appropriate type of area protection safety grid based on the specific requirements and characteristics of the scene, ensuring the safety and reliability of the system.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual