CL012 20K50K100K200Klb Column Canister Compresion Load Cell for truck scale

FOB Price
  • US $200.00

    1 - 10 piece

  • US $150.00

    11 - 100 piece

  • US $100.00

    101 - 500 piece

  • group namecanister and compression load cell

  • Min Order1 piece

  • brand nameInntronic

  • modelCL012

  • payment methodL/C

  • update timeThu, 21 Feb 2019 13:54:47 GMT

Paramtents

  • Pattern Column Cylinder Type

  • Transform Type Resistance Strain

  • Out-Wire 4-Wire

  • Output Signal Type Analog Type

  • Material Stainless Steel/Alloy Steel

  • Capacity 20K, 50K, 100K, 200K lb Load Cell

  • Interchagable with Rice Lake RL8C2P1SS Load Cell

  • Application Truck Scale

  • Zero Balance +-1.00% FS

  • Creep +-0.02% FS.

Packging & Delivery

  • Size32cm x 26cm x 27cm

  • Weight7.00kg / piece

  • Min Order1 piece

Briefing

Column Canister Compresion Load Cell ,Analog Load Cell,Alloy Steel,interchanble with Rice Lake RL8C2P1SS Load Cell

Detailed

CL012 20K to 200Klb Column Canister Compresion Load Cell for truck scale





 
20K, 50K, 100K, 200K Load Cell
 
Interchangeable Products
  • Artech 90405 Load Cell
  • BLH C2P1 Load Cell
  • Fairbanks 3-38065-X Load Cell
  • Fairbanks 3-38066-X Load Cell
  • HBM C-10 Load Cell
  • Mettler Toledo 10011900A Load Cell
  • Mettler Toledo 10014900A Load Cell
  • Mettler Toledo 10049200A Load Cell
  • Mettler Toledo 10049300A Load Cell
  • Revere 792 Load Cell
  • Rice Lake RL8C2P1SS Load Cell
  • Streeter Richardson 2011611 Load Cell
  • Streeter Richardson 2011612 Load Cell
  • Streeter Richardson 2011613 Load Cell
  • Streeter Richardson 2011614 Load Cell
  • Streeter Richardson 2011617 Load Cell
  • Totalcomp TC-C2P1 Load Cell

Technical data:

Capacity: 20K,50K,100K,200K (LB)

Rated output: 2.00mv/v +-0.25%

Safe Overload: 150% FS

Excitation Voltage: 10-20VDC

Input resistance: 385+-10ohms

Output resistance: 350+-5ohms

Zero Balance: +-1.00% FS

Seal Type: Hermetically sealed , IP67

Non-linearity: +-0.05% FS.

Hysteresis: +-0.03%FS

Repeatablity: +-0.01% FS.

Creep: +-0.02% FS.

Comply With NTEP rated.

Class III L 10,000 division,multiple cell

Compensated temperature range: -10 - 40

Temperature effect on zero:+-0.0027%FS/

Temperature effect on output+-0.0015%FS/

Insulation Resistance>5000MEGOHMS

Load cell cable: 4-24AWG,50FT,5.6MMPVC

Load cell wiring; Green +EXC  Black -EXC   White +SIG   Red -SIG Braid/Yellow: Shield

FM APPROVED