3100P : (3) - 5 - (7.5) - 10 - (15) - 20 - 30 - 50 - (75) - 100 - (150) - 200 - 300 - 500 t
Specifications C 1.5
Accuracy class 1500 d OIML -
Combined error < ± 0.035 % F.S.
Linearity error < ± 0.03 % F.S.
Repeatability error < ± 0.015 % F.S.
Creep error over 30 min. < ± 0.035 % F.S.
Zero shift after loading < ± 0.0075 % F.S.
Reference temperature 23 °C
Nominal temperature range -10...+45
Service temperature range -30...+70
Storage temperature range -50...+85
Temperature coefficient of the sensitivity < ± 0.017 % F.S./10°C
Temperature coefficient of zero signal < ± 0.025 % F.S./10°C
Zero balance± 0.02 mV/V
Sensitivity tolerance < ± 0.2 %
Insulation resistance (50V) > 5000 Megaohm
Reference excitation voltage 10 VDC
Nominal range of excitation voltage 3..12 VDC
Nominal sensitivity 1.5 mV/V
Safe load limit 1150 % F.S.
Breaking load >300 % F.S.
Static lateral force limit 15 % F.S.
Permissible dynamic loading 50 % F.S.
Input resistance 350..702 ± 2 Ohm
Output resistance 350..702 ± 2 Ohm