IPW6C 3kg to 40kg Single Point Load Cell for static weighing

  • group nameSingle Point Load Cell

  • Min Order1 piece

  • brand nameInntronic

  • modelIPW6C

  • payment methodL/C

  • update timeThu, 22 Mar 2018 21:26:27 GMT

Paramtents

  • Type Single Point Load Cell

  • Material Aluminum load cell

  • Capacity 3kg to 40kg

  • Sensitivity 2.0±0.2

  • Accuracy C3, C3MR

  • Input impedance 300 ... 500

  • Output impedance 300 ... 500

  • Zero balance 0±0.12

  • Application static weighing

  • IP Rating IP67

Packging & Delivery

  • Weight1.00kg / piece

  • Min Order1 piece

Briefing

load cell factory in China,Single Point Load Cell,Analog Load Cell,Aluminum Load Cell

Detailed

IPW6C 3kg to 40kg Single Point Load Cell 


Special features

-- Accuracy class C3 with OIML-R60 test report

-- Off center load compensated (OIML R 76)

-- Max. capacities: 3 kg ... 40 kg

-- Degree of protection IP67(according to EN 60 529)

-- Shielded connection cable

-- Optimized for static weighing applications

Optional:

-- Accuracy class C6 with OIML-R60 test report

-- Connection cable in six wire circuit

-- Different cable lengths

Aligned output, suitable for connectionin parallel


Type

IPW6C

Accuracy class1)

C3; C3MR

Number of load cell intervals (nLC)

3000

Maximum capacity (Emax)2))

kg

3

5

10

15

20

30-

40

 

Minimum LC verification interval (vmin)

Accuracy class C3

g

10

10

20

20

50

50

50

Temperature effect on

zero balance (TK0)

Accuracy class C3

 

% v.

Cn /

10 K

 

±0.0233

±0.0280

±0.0280

±0.0186

±0.0350

±0.0233

±0.0350

Minimum LC verification interval (vmin)

Accuracy class C3MR

g

0.2

0.5

1

1

2

2

5

Temperature effect on

zero balance (TK0)

Accuracy class C3MR

% v.

Cn /

10 K

 

±0.0093

±0.0140

±0.0140

±0.0093

±0.0140

±0.0093

±0.0175

Max. platform size

mm

300 x 300

Sensitivity (Cn)

mV/V

2.0±0.2

Zero balance

0±0.12

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40  [+68 ... +104]

−10 ... +20  [+14 ... +68]

% v.

Cn /

10 K

 

±0.0175

±0.0117

Hysteresis error (dhy)3)

% of Cn

±0.0166

Non-linearity (dlin)3)

±0.0166

Minimum dead load output return (DR)

±0.0245

Off center load error4)

±0.0233

Input resistance (RLC)

Ω

300 ... 500

Output resistance (R0)

300 ... 500

Reference excitation voltage (Uref)

V

5

Nominal range of excitation voltage (BU)

1...12

Insulation resistance (Ris) at 100 VDC

> 2

Nominal temp. range (BT)

°C

[°F]

−10 ... +40 [+14 ... +104]

Service temp. range  (Btu)

−10 ... +50 [+14 ... +122]

Storage temp. range (Btl)

−25 ... +70 [−13 ... +158]

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150

100

Lateral load limit (Elq), static

% of

Emax

300

Breaking load (Ed)

300

Deflection at Emax (snom), approx.

mm

< 0.5

Weight (G), approx.

kg

0.25

Protection class according to

EN 60 529 (IEC 529)

 

IP67

Material: Measuring element

Coating

Cable sheath

 

Aluminum

Silicone rubber

PVC