group nameSingle Point Load Cell
Min Order1 piece
brand nameInntronic
modelIPW12C
payment methodL/C
update timeThu, 22 Mar 2018 21:26:54 GMT
Type Single Point Load Cell
Material Aluminum
Capacity 50 kg to 750 kg
Sensitivity 2.0
Accuracy C3
Input impedance 300 ... 500
Output impedance 330 ... 430 (Option 6: A = 410 Ω
Zero balance 0±0.1
Application platform scale
Protection class IP67
Weight1.00kg / piece
Min Order1 piece
Type | IPW12C | ||||||||||
Accuracy class1) | C3; C3MR | ||||||||||
Number of load cell intervals (nLC) | 3000 | ||||||||||
Maximum capacity (Emax)2)) | kg | 50 | 75 | 100 | 150 | 200 | 250 | 300 | 500 | 635 | 750 |
Minimum LC verification interval (vmin) Accuracy class C3 | g | 10 | 10 | 20 | 20 | 50 | 50 | 50 | 100 | 100 | 100 |
Temperature effect on zero balance (TK0) Accuracy class C3 | % v. Cn / 10 K | ±0.0280 | ±0.0186 | ±0.0280 | ±0.0186 | ±0.0350 | ±0.0280 | ±0.0233 | ±0.0280 | ±0.0221 | ±0.0186 |
Minimum LC verification interval (vmin) Accuracy class C3MR | g | 5 | 5 | 10 | 10 | 20 | 20 | 20 | 50 | 50 | 50 |
Temperature effect on zero balance (TK0) Accuracy class C3MR | % v. Cn / 10 K | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0112 | ±0.0093 | ±0.0140 | ±0.0110 | ±0.0093 |
Max. platform size | mm | 800 x 800 | |||||||||
Sensitivity (Cn) | mV/V | 2.0±0.2 (Option 6: A = 2mV/V±0.1%) | |||||||||
Zero balance | 0±0.1 | ||||||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K | ±0.0175 ±0.0117 | |||||||||
Hysteresis error (dhy)3) | % of Cn | ±0.0166 | |||||||||
Non-linearity (dlin)3) | ±0.0166 | ||||||||||
Minimum dead load output return (DR) | ±0.0166 | ||||||||||
Off center load error4) | ±0.0233 | ||||||||||
Input resistance (RLC) | Ω | 300 ... 500 | |||||||||
Output resistance (R0) | 330 ... 430 (Option 6: A = 410 Ω±0.2 Ω) | ||||||||||
Reference excitation voltage (Uref) | V | 5 | |||||||||
Nominal range of excitation voltage (BU) | 15 | ||||||||||
Max. excitation voltage | 15 | ||||||||||
Insulation resistance (Ris) at 100 VDC | GΩ | > 2 | |||||||||
Nominal temp. range (BT) | °C [°F] | −10 ... +40 [+14 ... +104] | |||||||||
Service temp. range (Btu) | −10 ... +50 [+14 ... +122] | ||||||||||
Storage temp. range (Btl) | −25 ... +70 [−13 ... +158] | ||||||||||
Safe load limit (EL ), at max. 100mm eccentricity | % of Emax | 150 | |||||||||
Lateral load limit (Elq), static | % of Emax | 300 | |||||||||
Breaking load (Ed) | 300 | ||||||||||
Deflection at Emax (snom), approx. | mm | < 0.5 | |||||||||
Weight (G), approx. | kg | 2.4 | |||||||||
Protection class according to EN 60 529 (IEC 529) | IP67 | ||||||||||
Material: Measuring element Coating Cable sheath | Aluminum Silicone rubber PVC |
1) In accordance to OIML-R60 with P = 0.7
2) Max. eccentric load according to OIML R76
3) The sum of data for Non-linearity, Hysteresis error and TC Span meets the requirements of OIML R60
4) Eccentric error according to OIML R76
− OIML-R60 approval
−Max. Capacities: 50 kg...750 kg
−Off center load compensated
(OIML R76)
−Meets EMC standards
(EN 45 501)
−6-wire circuit
Optional:
−Reduced minimum LC verification interval (vmin) for multi range applications
−Explosion-proof versions
−Different cable lengths
−Aligned output, suitable for connection in parallel