group nameSingle Point Load Cell
Min Order1 piece
brand nameInntronic
modelIN-SP4MC6MR
payment methodL/C
update timeThu, 22 Mar 2018 21:26:13 GMT
Type Single Point Load Cell
Material Aluminum load cell
Capacity 7 to 36 kg
Sensitivity 2.0 ±10 % 1.8 ±10 % 2.4 ±10 %
Accuracy C3MR
Input impedance 300 ... 500
Output impedance 300 ... 500
Zero balance 0±0.1
IP Rating IP67
Application multi range
Weight1.00kg / piece
Min Order1 piece
Type | ISP4MC6MR | ||||||||
Accuracy class1) | C6MR | ||||||||
Number of load cell intervals (nLC) | 6000 | ||||||||
Maximum capacity (Emax)2)) | kg | 7 | 10 | 15 | 18 | 36 | |||
Minimum LC verification interval (vmin) Accuracy class C3 | g | 0.1 | 0.2 | 0.5 | 0.5 | 1 | |||
Temperature effect on zero balance (TK0) Accuracy class C3 | % v. Cn / 10 K | ±0.0140 | ±0.0093 | ±0.0140 | ±0.0100 | ±0.0140 | |||
Max. platform size | mm | 300 x 300 | 450 x 450 | ||||||
Sensitivity (Cn) | mV/V | 2.0 ±10 % | 1.8 ±10 % | 2.4 ±10 % | |||||
Zero balance | 0±0.1 | ||||||||
Temperature effect on sensitivity (TKC)3) Temperature range +20 ... +40℃ [+68 ... +104℉] −10 ... +20℃ [+14 ... +68℉] | % v. Cn / 10 K | ±0.0087 ±0.0058 | |||||||
Hysteresis error (dhy)3) | % of Cn | ±0.0083 | |||||||
Non-linearity (dlin)3) | ±0.0166 | ||||||||
Minimum dead load output return (DR) | ±0.0083 | ||||||||
Off center load error4) | ±0.0116 |