Various Cable Lengths Stainless Steel Load Cell Off ‐ Center Load Compensated

  • group nameSingle Point Load Cell

  • Min Order1 piece

  • brand nameInntronic

  • modelIPW15B

  • payment method

  • update timeThu, 16 Aug 2018 14:56:00 GMT

Paramtents

  • pattern single point load cell

  • capacity 7.5kg to 200kg

  • output 2mv/v

  • material Stainless steel

  • application platform scale

  • interchangeable brand HBM

  • IP protection standard IP67

  • accuracy C3

  • Non-linearity 0.0166

  • size 150*25*40

Packging & Delivery

  • Min Order1 piece

Briefing

Various Cable Lengths Stainless Steel Load Cell Off ‐ Center Load Compensated

Detailed

IPW15A 7.5kg to 200kg Single Point Load Cell


Special features

-  Stainless steel
-  Maximum capacities:7.5 kg...200 kg
-  Constricted minimum scale interval (v min ) for multirange applications
-  OIML R60 test report
-  Off‐center load compensated (OIML R 76)
-  Degree of protection IP67 (per EN60529)
-  6‐wire configuration
-  Meets EMC guidelines (EN 45501)
Optional:

-  Explosion‐proof versions
-  Various cable lengths
-  Aligned output, suitable for
   parallel connection

TypeIPW15B
Accuracy class1)C3MR
Number of load cell intervals (nLC)3000
Maximum capacity (Emax)2))kg7.51520305075100150200 

Minimum LC verification interval (vmin)

Accuracy class C3

g0.512255101020 

Temperature effect on

zero balance (TK0)

Accuracy class C3


% v.

Cn /

10 K


±0.0093±0.0093±0.0140±0.0093±0.0140±0.0093±0.0140±0.0093±0.0140 
Max. platform sizemm500 x 400
Sensitivity (Cn)mV/V2.0±0.2 (Option 6: A = 2mV/V±0.1%)
Zero balance0±0.1

Temperature effect on

sensitivity (TKC)3)

Temperature range

+20 ... +40℃ [+68 ... +104℉]

−10 ... +20℃ [+14 ... +68℉]

% v.

Cn /

10 K


±0.0175

±0.0117

Hysteresis error (dhy)3)% of Cn±0.0166
Non-linearity (dlin)3)±0.0166
Minimum dead load output return (DR)±0.0166
Off center load error4)±0.0233
Input resistance (RLC)Ω380±15
Output resistance (R0)359±5(Option 6: 359±0.2 Ω)
Reference excitation voltage (Uref)V5
Nominal range of excitation voltage (BU)1-12
Max. excitation voltage15
Insulation resistance (Ris) at 100 VDC> 1
Nominal temp. range (BT)

°C

[°F]

−10 ... +40
Service temp. range (Btu)−10 ... +50
Storage temp. range (Btl)−25 ... +70

Safe load limit (EL ), at max.

100mm eccentricity

% of

Emax

150
Lateral load limit (Elq), static

% of

Emax

300
Breaking load (Ed)300
Weight (G), approx.kg1

Protection class according to

EN 60 529 (IEC 529)

 IP67

Material: Measuring element

Coating

Cable sheath

 

Steel 1.4545

Silicone rubber

PVC