YOKOGAWA EJA430E liquid gas steam differential pressure transmitter

FOB Price
  • US $650.00

    1 - 1 piece

  • US $410.00

    2 - 10 piece

  • group namePressure transmitter

  • Min Order1 piece

  • brand nameShelok

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeMon, 17 Sep 2018 13:42:11 GMT

Packging & Delivery

  • Min Order1 piece

Briefing

EJA430E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam pressure.

Detailed

The high performance gauge pressure transmitter EJA430E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam pressure. The EJA430E outputs a 4 to 20 mA DC signal corresponding to the measured pressure. It also features quick response, remote setup and monitoring via BRAIN or HART communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available. All EJA-E series models in their standard configuration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certified as complying with SIL 2 for safety requirement.PERFORMANCE SPECIFICATIONS Zero-based calibrated span, linear output, wetted parts material code ‘S’ and silicone oil, unless otherwise mentioned. For Fieldbus and PROFIBUS PA communication types, use calibrated range instead of span in the following specifications. Specification Conformance EJA-E series ensures specification conformance to at least ±3σ. Reference Accuracy of Calibrated Span (includes the effects of terminal-based linearity, hysteresis, and repeatability)Stability (All normal operating condition) ±0.1% of URL per 10 years Power Supply Effects(Output signal code D and J) ±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω) Vibration Effects Amplifier housing code 1 and 3: Less than 0.1% of URL when tested per the requirements of IEC60770-1 field or pipeline with high vibration level (10-60 Hz, 0.21 mm displacement/60-2000 Hz 3 g) Amplifier housing code 2: Less than ±0.1% of URL when tested per the requirements of IEC60770-1 field with general application or pipeline with low vibration level (10-60 Hz 0.15mm displacement /60-500 Hz 2g) Mounting Position Effects Rotation in diaphragm plane has no effect. Tilting up to 90 degree will cause zero shift up to 0.4 kPa (1.6 inH2O) which can be corrected by the zero adjustment. Response Time (All capsules)90 ms 150 ms for H capsule with Wetted Parts Material code H, M, T, A, D, B and W. When software damping is set to zero and including dead time of 45 ms (nominal)FUNCTIONAL SPECIFICATIONS Output For 4 to 20 mA HART / BRAIN (Output signal code D and J) Two wire 4 to 20 mA DC output with digital communications, linear or square root programmable. BRAIN or HART FSK protocol are superimposed on the 4 to 20 mA signal. Output range: 3.6 mA to 21.6 mA Output limits conforming to NAMUR NE43 can be pre-set by option code C2 or C3. For 1 to 5 V HART (Output signal code Q) Three or four wire low power 1 to 5 V DC output with HART, linear or square root programmable. HART protocol are superimposed on the 1 to 5 V DC signal. Output range: 0.9 V to 5.4 V DC Failure Alarm For 4 to 20 mA HART / BRAIN (Output signal code D and J) Output status at CPU failure and hardware error; Up-scale: 110%, 21.6 mA DC or more (standard) Down-scale: ?5%, 3.2 mA DC or less For 1 to 5 V HART (Output signal code Q) Analog output status at CPU failure and hardware error; Up-scale: 110%, 5.4 V DC or more (standard) Down-scale: ?5%, 0.8 V DC or less Damping Time Constant (1st order) Amplifier’s damping time constant is adjustable from 0.00 to 100.00 s by software and added to response time. Note: For BRAIN protocol type, when the software damping is set to less than 0.5 s, communication may occasionally be unavailble during the operation, especially while output changes dynamically. The default setting of damping ensures stable communication. Update Period Pressure: 45 ms Zero Adjustment Limits Zero can be fully elevated or suppressed, within the lower and upper range limits of the capsule. External Zero Adjustment External zero is continuously adjustable with 0.01% incremental resolution of span. Re-range can be done locally using the digital indicator with rangesetting switch. Integral Indicator (LCD display) 5-digit numerical display, 6-digit unit display and bar graph. The indicator is configurable to display one or up to three of the following variables periodically.; pressure in %, scaled pressure, measured pressure. See also “Factory Setting”. Local Parameter Setting (Output signal code D, J and Q) Parameter configuration by the external zero adjustment screw and push button (Integral indicator code E) offers easy and quick setup for parameters of Tag number, Unit, LRV, URV, Damping, Output mode (linear/square root), Display out 1, and Re-range by applying actual pressure (LRV/URV).Burst Pressure Limits 69 MPa (10,000 psi) for wetted parts material S and L. 47 MPa (6,800 psi) for wetted parts material other than S and L. Self Diagnostics CPU failure, hardware failure, configuration error, and over-range error for pressure and capsule temperature. User-configurable process high/low alarm for pressure is also available. Signal Characterizer (Output signal code D, J and Q) User-configurable 10-segment signal characterizer for 4 to 20 mA output. SIL Certification All the EJA-E series transmitters except Fieldbus, PROFIBUS PA and 1-5V DC with HART (Low Power) communication types are certified in compliance with the following standards; IEC 61508: 2010; Part1 to Part 7 Functional Safety of Electrical/electronic/ programmable electronic related systems; SIL 2 capability for single transmitter use, SIL 3 capability for dual transmitter use. NORMAL OPERATING CONDITION (Optional features or approval codes may affect limits.) Ambient Temperature Limits ?40 to 85°C (?40 to 185°F) ?30 to 80°C (?22 to 176°F) with LCD display Process Temperature Limits ?40 to 120°C (?40 to 248°F) Ambient Humidity Limits 0 to 100% RHSupply Voltage For 4 to 20 mA HART / BRAIN (Output signal code D and J) 10.5 to 42 V DC for general use and flameproof type. 10.5 to 32 V DC for lightning protector (option code /A.) 10.5 to 30 V DC for intrinsically safe, type n, or nonincendive type. Minimum voltage limited at 16.6 V DC for digital communications, BRAIN and HARTFor 1 to 5 V HART (Output signal code Q) Power supply : 9 to 28 V DC for general use and flame proof type. Power Consumption : 0.96 mA to 3 mA, 27 mW Load for 4 to 20 mA HART / BRAIN (Output signal code D and J) 0 to 1290Ω for operation 250 to 600Ω for digital communication Output Load for 1 to 5 V HART (Output signal code Q) 1 MΩ or greater (meter input impedance) Note that with three-wire connection, the cable length may affect the measurement accuracy of the output signal. Communication Requirements (Approval codes may affect electrical requirements.) BRAINCommunication distance Up to 2 km (1.25 miles) when using CEV polyethylene-insulated PVC-sheathed cables. Communication distance varies depending on type of cable used. Load capacitance 0.22 μF or less Load inductance 3.3 mH or less Input impedance of communicating device 10 kΩ or more at 2.4 kHz. EMC Conformity Standards EN 61326-1 Class A, Table2 EN 61326-2-3 EN 61326-2-5 (for fieldbus) European Pressure Equipment Directive 2014/68/EU Sound Engineering Practice EU RoHS Directive EN 50581 Safety Requirement Standards EN 61010-1, C22.2 No.61010-1 ? Installation category: I (Anticipated transient overvoltage 330 V) ? Pollution degree: 2 ? Indoor/Outdoor use □ PHYSICAL SPECIFICATIONS Wetted Parts Materials Diaphragm, cover flange, process connector, capsule gasket, and vent/drain plug Refer to “MODEL AND SUFFIX CODES.” Process connector gasket PTFE Teflon Fluorinated rubber for option code N2 and N3June 1, 2017-00Non-wetted Parts Materials Bolting B7 carbon steel, 316L SST or 660 SST Housing ? Low copper cast aluminum alloy ? Low copper cast aluminum alloy with corrosion resistance properties (copper content ≤ 0.03%, iron content ≤ 0.15%) (optional) ? ASTM CF-8M Stainless steel (optional) Coating of housing [for aluminum housing] Urethane curing type polyester resin powder coating Deep sea moss green paint (Munsell 0.6GY3.1/2.0 or its equivalent) [for option code /P? or /X2] Epoxy and polyurethane resin solvent coating Degrees of protection IP66/IP67, Type 4X Cover O-rings Buna-N, fluoro-rubber (optional) Name plate and tag 316 SST Fill fluid Silicone, Fluorinated oil (optional) Weight [Installation code 7, 8 and 9] 2.8 kg(6.2 lb) for wetted parts material code S and L, without integral indicator, mounting bracket, and process connector. Add 1.5 kg (3.3lb) for Amplifier housing code 2. Connections Refer to “MODEL AND SUFFIX CODES.” Process connection of cover flange: IEC61518