group nameAnesthesia Machine
Min Order10 piece
modelCNME010307
payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
update timeMon, 12 Jul 2021 13:41:33 GMT
Type Anaesthesia Machine
Kind Anesthesia Machine
Certification CE
Group Adult, Pediatric
LCD Display With LCD Display
Source Air, O2, N2o
Min Order10 piece
Model NO. | CNME010307 | ||
Product Name | Anesthesia Machine | ||
Display | 10.4" TFT Color Screen | ||
Driven Mode | Pneumatically Driven and Electronically Controlled | ||
Patient Types | Adult and Pediatric Populations Weighing Above 2kg | ||
Ventilation Modes | Ippv, Pcv, Simv+PS, PS and Manual | ||
Setting Modes | Touch Key & Navigator Wheel | ||
Vaporizer | Support Two Vaporizers | ||
Agent | Halothane, Enflurane, Isoflurane, Sevoflurane | ||
Operational Modes | Closed, Semi-Closed, Semi-Open | ||
Tidal Volume | 20~1500ml | ||
Ventilation Frequency | 4~100bpm | ||
Specification | Dimensions(W*H*D): 704mm*1403mm*750mm(without YOKE | ||
Origin | China |
product name
|
Breathing System 10.4 TFT Color Screen Anesthesia Ventilation Machine with Two Vaporizers
|
|
Physical & Environment Specifications
|
Dimensions(W×H×D): 704mm × 1403mm × 750mm(without YOKE) Weight: 100kg (basic unit) Operation Temperature: +10~+40°C Operation Humidity: ≤80% (noncondensing) Storage Temperature: -20~+60°C Storage Humidity: ≤95% (noncondensing) |
|
Electrical Specifications | Mains: 100~240V AC, 50/60Hz Battery: 24V 4Ah, minimum 120 min Outlets: 3 on back, 1.5A individual | |
Pneumatic Specifications | Gas Supply: Air, O2, N2O; 280kPa ~ 600kPa Flowmeters: O2 Range: 0~1L/min; 1~10L/min N2O Range: 0~1L/min; 1~10L/min Air Range: 0~1L/min; 1~12L/min Auxiliary O2 Range: 0 ~12 L/min Flowmeter backlight Gas System: Oxygen supply failure alarm Oxygen supply failure protection O2 flush: 25~75L/min ACGO: Optional auxiliary common gas outlet AGSS: Optional anesthetic gas scavenging system | |
Breathing System Specifications | Operational Modes: Closed, Semi-closed, Semi- open CO2 Canister: 2 Loose fill (3L) or 2 prepacks, optional single canister APL Range: Spontaneous breathing (SP) - 70 cmH2O Material: Autoclavable (except O2 cell and mechanical pressure gauge) Heating system: Optional CO2 bypass: Optional | |
Breathing System Specifications | Operational Modes: Closed, Semi-closed, Semi- open CO2 Canister: 2 Loose fill (3L) or 2 prepacks, optional single canister APL Range: Spontaneous breathing (SP) - 70 cmH2O Material: Autoclavable (except O2 cell and mechanical pressure gauge) Heating system: Optional CO2 bypass: Optional | |
Ventilator Specifications | Driven Mode: Pneumatically driven and electronically controlled Patient Types: Adult and Pediatric populations weighing above 2kg Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual Setting Modes: Touch key & navigator wheel knob Tidal Volume: 20~1500ml Ventilation Frequency: 4~100bpm I:E Ratio: 4:1~1:8 Pressure (inspired) Range: 5~70cmH2O Pressure (support) Range: 3~50cmH2O PEEP: Off,3~30 cmH2O Tslope: 0~2s Inspiratory Plateau: Off, 5%~60%Ti Trigger Sensitivity: 1~15L/min Compensation: Compliance and leakage compensation, fresh gas compensation and altitude compensation | |
Ventilator Specifications | Display: 10.4" TFT color screen Pressure: Paw, Ppeak, Pplat, Pmean, PEEP Volumes: MV, Vt, Freq Gas: FiO2, optional: CO2, AG, MAC Graph Display: P-t, F-t, P-V, F-V and optional CO2-t Alarm: High Airway Pressure/Low Airway Pressure Sustained airway pressure High Minute Volume/Low Minute Volume High FiO2/Low FiO2 High Breath Rate O2 Supply failure Power failure Apnea Alarm Alarm Silence: 110 seconds | |
Vaporizer | Support two vaporizers Agent: Halothane, Enflurane, Isoflurane, Sevoflurane Installation Mode: Selectatec with interlock, optional standby vaporizer parking holder Filling Type: Pour Fill, Key Fill, Quik-Fil |
网络文化经营许可证:浙ICP备14006100号-11 2007-2024 Tradevv.com. All rights reserved.