Professional 15" LCD Touch Screen Anesthesia Machine in ICU and Operating Room

  • group nameAnesthesia Machine

  • Min Order2 piece

  • modelCNME010320

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeMon, 12 Jul 2021 13:41:33 GMT

Paramtents

  • Type Anesthesia Machine

  • Kind Surgical Equipment

  • Certification CE

  • Group All

  • Display 15 Inch LCD Touch Screen

  • Ventilation Mode Ippv, A/C, Pcv,Psv, Simv, Sigh, Manual

Packging & Delivery

  • Min Order2 piece

Briefing

Professional 15" LCD Touch Screen Anesthesia Machine in ICU,The AC power failure alarm: Power failure or no connection.

Detailed

Professional 15" LCD Touch Screen Anesthesia Machine in ICU and Operating Room

Basic Info.
Model NO.
CNME010320
Power
Built-in Battery Ensure 2-3 Hours Using
Alarm
Three Level Alarm System
Rapid Oxygen Supply
25L/Min~75L/Min
Tidal Volume(Vt)
0, 20ml~1500ml
Frequence (Freq)
1/Min~100/Min
I:E
4:1~1:8
Peep
0 CMH2o~30 CMH2o
Pressure Triggering Sensitivity (Ptr)
-20 CMH2o~0 CMH2o(Based on Peep)
Flow Trigger Sensitivity (Ftr)
0.5 L/Min ~ 30 L/Min
Pressure Control (PC)
5 CMH2o~60 CMH2o
Sigh
0(off) 1/100 ~ 5/100
Oscillogram
P-T, F-T, V-T, Etco2-T, P-V/P-F/F-V Loop
Origin
China
Professional 15" LCD Touch Screen Anesthesia Machine In ICU and Operating Room
Description:
Patient Centered Ventilation: Precision in an anesthesia ventilator, from conventional ventilation to advanced modes and adapt to wide range patient.
Safety design: Vaporizer with temperature, pressure, flow compensation and self-lock function. Real time pressure-time, flow-time loop oscillogram and high precision ETCO2, O2 concentration detection function included.
Three oscillograms and three loops at the same time
Alarm: Three level alarm system, visual and sound alarm information
Power: Built-in battery ensure 2-3 hours using when power failure
Separate design of electric circuit and gas circuit ensure long using life
Flexible configurations able to customize your requirements
Specification:
Product name
Professional 15" LCD Touch Screen Anesthesia Machine in ICU and Operating Room
Ventilation mode
IPPV, A/C, PCV,PSV, SIMV, SIGH, MANUAL
Monitoring parameter
Frequence (Freq): 0/min~100/min
Tidal volume(Vt): 0mL~2000mL
MV: 0L/min~100L/min
Oxygen concentration: 15%~100%
Oscillogram
P-T (pressure - time)
F-T (flow- time)
V-T (volume - time )
ETC02-T (ETC02 - time)
P-V / P-F/ F-V loop
Working condition
Gas source: O2, N2O, AIR
Pressure: 280kPa~600kPa
Voltage: 100~240V
Power frequency: 50/60Hz
Packing size
Wooden case packing size: L87*100*160cm
N.W./ G.W: 165/240KG
Wooden case packing size: L55*73*67cm
N.W./G.W: 45/60KGS
Anesthesia Machine Detailed Description:
Optional part 1
Anesthetic gas monitor, Vital Signs Monitor:
Real-time monitoring of anesthetic gas and patient's physiological condition
Optional part 2
AGSS: To enhance the safety of the environment in which members of staff in close proximity with waste anesthetic gases and vapors (agents)work.
Ventilator parameter range
Flowmeter: O2(0.1~10L/min)
                   N2O(0.1~10L/min)
                   AIR(0.1~10L/min)
Rapid oxygen supply:  25L/min~75L/min
Tidal volume(Vt):  0, 20ml~1500ml
Frequence (Freq):  1/min~100/min
I:E:   4:1~1:8
PEEP:  0 cmH2O~30 cmH2O
Pressure triggering sensitivity (PTr):  -20 cmH2O~0 cmH2O(Based on PEEP)
Flow trigger sensitivity (FTr):  0.5 L/min ~ 30 L/min
Pressure control (PC):  5 cmH2O~60 cmH2O
SIGH:  0(off) 1/100 ~ 5/100
Apnea ventilation:  OFF, 5s~60s
Pressure limit:  20 cmH2O~100 cmH2O

Alarm and protection
The AC power failure alarm: Power failure or no connection
Internal battery backup low voltage alarm < 11.3±0.3 V
No tidal volume: ≤5 ml within 6s
High oxygen concentration alarm: 19% ~ 100%
Low oxygen concentration alarm: 18% ~ 99%
High airway pressure alarm: 20 cmH2O~100 cmH2O
Low airway pressure alarm: 0 cmH2O~20 cmH2O
High minute volume alarm: Adult (5 L/min -20 L/min)
Low minute volume alarm: Paed (1 L/min -15 L/min, 0-10 L/min)
Continuous pressure alarm: (PEEP+1.5kPa) over 16s
Suffocation warning: 5s-60s no spontaneous ventilation
The maximum limited pressure: <12.5 kPa
Fan error: Show on screen
Oxygen deficit: Show on screen
Anesthesia Machine Real Scene Shoots:
More Options for your selection