group nameMedical X-Ray Equipnent
Min Order2 piece
modelXrx-DRM01
payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal
update timeMon, 12 Jul 2021 13:41:53 GMT
Type X Ray Equipment
Group All People
Certification CE, MSDS, ISO13485
Output Power 5.6kw
Radiography Tube Current 10-100mA
Classification Imaging Diagnostic Equipment
Min Order2 piece
Model NO. | Xrx-DRM01 | ||
Power Supply | 220V, 50kHz | ||
Inverter Frequency | 50kHz | ||
Radiography Tube Voltage | 40-120kv | ||
Battery | Available Lithium | ||
Touch Screen | 8 Inch | ||
Operation Method | Wire/ Wireless Control | ||
After-Sales Service | Whole Using Lifetime | ||
Transport Package | PWooden Case | ||
Specification | 650cm*300cm*190cm | ||
Origin | China |
Item
|
Specification
|
|
1. High voltage generator | ||
1.1
|
standard output power:5.6kW
|
|
1.2 | mA range:10-100mA | |
1.3 | Tube voltage range:40-125kV | |
1.4 | mAs range :0.1-200mAs | |
1.5 | Load time range:0.002s~4s | |
1.6 | High voltage transformer structure:The power frequency | |
2. X-ray tube | ||
2.1 | Focus range:0.6/1.8mm | |
2.2 | Anode types: fixed anode | |
2.3 | The maximum voltage:125kV | |
2.4 | Anode angle 15° | |
2.5 | The inherent filtration:0.6mm Al/75kV | |
3. Collimator | ||
3.1 | The inherent filtration:1 mm Al /70 kV; | |
3.2 | Collimator is equipped with LED lights(Bright 30S are automatically extinguished) | |
3.3 | Collimator is built into measuring ruler | |
4. The tube bracket structure | ||
4.1 | SID: 330 ~ 1650mm | |
4.2 | Size after folding:1060*400*400mm | |
4.3 | weight:32KG | |
5. Detector(iRay) | ||
5.1 | WIFI connection, Amorphous Silicon oxide ,whole panel technology | |
5.2 | The effective camera size of the detector:350mm×430mm | |
5.3 | Pixel size:150 µm | |
5.4 | Gathering matrix:≥2304×2800pixels | |
5.5 | Spatial resolution≥3.4lp/mm | |
5.6 | Pixel gray level:≥14bit | |
5.7 | Detector cooling mode: natural cooling | |
6. Digital image workstation | ||
6.1 | CPU frequency:CORE i3 | |
6.2 | Memory capacity:4GB | |
6.3 | Hard drive capacity:500 GB | |
6.4 | 64 bit Windows operation system | |
7. Image acquisition software | ||
7.1 | Patient registration: acquisition, find the patient data, to prepare for the photography | |
7.2 | Images display, image analysis, processing and output | |
7.3 | Data management: managing patient data, leading in, leading out , batch file, etc in accordance with DICOM3.0,5.4AH | |
7.4 | System diagnosis: monitoring system status, diagnosis of the system fault | |
8 . Battery | ||
8.1.1 | Power supply way | |
8.1.2 | Lithium battery supply | |
8.1.3 | The rated capacity:32.4V | |
8.2 | Battery capacity: More than 100 exposures, (Exposure conditions: 50kV,80mA,20ms ) | |
8.3 | Dual power supply, exposure under either wall current or lithium battery | |
8.4 | Maximum charging 4 hours | |
8.5 | The standby time is not less than 7 hours | |
8.6 | Can support handswitch and remote control exposure | |
9. The machine parameters | ||
9.1 | Appearance size | |
9.1.1 | Whole machine width:240 mm | |
9.1.2 | Whole machine length:440 mm | |
9.1.3 | Whole machine height:236 mm | |
9.2 | Whole weight(no detector):18kg | |
10. Options | ||
10.1 | Wireless network data transmission(WIFI) | |
10.2 | Choose a chest rack | |
10.3 | The selection of moving flat bed |