Medical Equipment High Frequency Mobile Digital C-Arm X-ray Machine

  • group nameMedical X-Ray Equipnent

  • Min Order2 piece

  • modelXrC12E

  • payment methodL/C, D/A, D/P, Western Union, MoneyGram, T/T, Paypal

  • update timeMon, 12 Jul 2021 13:41:53 GMT

Paramtents

  • Classification Imaging Diagnostic Equipment

  • Type X Ray Equipment

  • Certification CE, MSDS, ISO13485

  • Group Middle-aged and Old

  • Output Power 5.0kw

  • Mas 1~180mas

Packging & Delivery

  • Min Order2 piece

Briefing

Medical Equipment High Frequency Mobile Digital C-Arm X-ray Machine,With a compact appearance, and easy to operate.

Detailed

Medical Equipment High Frequency Mobile Digital C-Arm X-ray Machine

Basic Info.
Model NO.
XrC12E
Radiography Tube Current
50mA 100mA
Power Supply
220V,50kHz
Inverter Frequency
40kHz
Dual Focus
Small Focus: 0.3 Large Focus :1.5 Mas
Radiography Tube Voltage
40-120kv
Operation Method
Manual
After-Sales Service
Whole Using Lifetime
Specification
2000mmx665mmx700mm
Transport Package
Wooden Case
Origin
China
Medical Equipment High Frequency Mobile Digital C-Arm X-ray Machine
Usage:
Orthopaedics: osteopathy, diaplasis, nailing
Surgery: removing foreign body, cardiac catheter, implanting pace maker, interventional therapy, partial radiography, local photography, and other work.

1. With a compact appearance, and easy to operate
2. Unique base electric auxiliary support arm design, it's more security for using. 
3. A unique hand-held controller design, convenient to operate
4. With a high-quality knockdown X-ray generator to reduce radiation
5. With the Perspective KV,MA automatically track fluoroscopy to make the image brightness and clearness optimum
6. Toshiba image intensifier, the quality is stable and reliable, a good image clarity
7. Clinical Video system with high performance,8 images storage  volume, and one 14inchhigh-resolution monitors
8. Installation of dense grain grids, to further enhance image sharpness
Specifications:
1. Fluoroscopic Capacity 
   Max rated capacity  : Tube Current 4mA, Tube Voltage 120kV 
   Automatic Fluoroscopy   : Tube Voltage:40kV~120kV Adjust  Automatically
   Tube Current  : 0.3mA~4mA Manually Settings
   Manual Fluoroscopy : Continuous Tube Voltage:40kV~120kV
   Continuous Tube Current  : 0.3mA~4mA 
   Pulse Fluoroscopy :   Continuous Tube Voltage 40kV~120kV 
                                     Continuous Tube Current 4.1mA~8mA  
2. Photography Capacity 
  Max rated capacity      :  5 KW 
  Tube Voltage and Current Combination   :   40kV~49kV   1 ~180 mAs
                                                                         50kV~59kV   1 ~140 mAs
                                                                         60kV~69kV   1 ~125  mAs
                                                                         70kV~79kV   1 ~110 mAs
                                                                         80kV~89kV   1 ~100 mAs
                                                                         90kV~99kV   1 ~80  mAs
                                                                         100kV~109kV 1 ~63  mAs 
110kV~120kV 1 ~50  mAs 
  Plate holder Size  :  200mm×250mm(8″×10″)or 
                                  250mm×300mm(10″×12″) 
3. X-ray Tube 
X-ray Tube Special for High Frequency 
Fixed anode  Dual-focus: large focus:  1.5, small focus: 0.3mm*0.3mm (Advantage)
Inverter Frequency   :  40KHz
Thermal capacity  :  35KJ (47KHU) 
4.Video System 
 Image Intensifier  : Image Intensifier made by TOSHIBA (9″, 6″,4.5″) 
 CCD Vidicon  : Ultra low-light CCD camera imported from Japan
 Monitor  :Horizontal 1000 lines and vertical 800 lines,  Bandwidth : 12.5MHz,  Image/sec : 75  
CCU(central control) : Recursive Filter: K=8,8 images storage,  image upright, image overturn,positive &  negative image;LIH(last Image Hold) and OSD(monitor display) 
5.Structure: 
 Directive wheel  : ±90°revolution,can freely change the moving  direction of the unit . 
 Ascending & Descending Range of Pillar : ≥400mm 
 C-arm : Forward and Backward Movement: 200mm
 Revolution around Horizontal Axis:  ±180°
 Revolution around Vertical Axis  :  ±15°( Advantage), better than others'  ±12.5°, easier  to take special positions radiography )
 Slip on orbit: 120°(+90°~ -30°)
More Options for your selection