DT11 series|PVC safety Mats|DADISICK

  • group nameSafety Mats

  • Min Order1 piece

  • brand nameDADISICK

  • modelDT11 series

  • update timeWed, 01 May 2024 20:56:32 GMT

Paramtents

  • Detection method: Pressure sensing method

  • Maximum allowable dynamic load: Impact load<200kg/cm²

  • PVC anti slip surface layer: Anti slip grade R9

  • Encapsulation and Surface Protection: PVC

  • IEC 61508:PFHS 9.99*10 1/h(SIL3)

Packging & Delivery

  • Min Order1 piece

Briefing

Safety carpet is a technology that monitors the pressure distribution on the carpet through pressure sensing.

Detailed

Model Specifications

Safety pad size (L1×L2)
DT11 type
NBR overall package anti-rolling type
Thickness 15mm
30cmx30cm
DT11-30X30
40cmx40cm
DT11-40X40
50cmx25cm
DT11-50X25
50cmx40cm
DT11-50X40
50cmx50cm
DT11-50X50
60cmx40cm
DT11-60X40
75cmx25cm
DT11-75X25
75cmx50cm
DT11-75X50
75cmx75cm
DT11-75X75
100cmx25cm
DT11-100X25
100cmx50cm
DT11-100X50
100cmx75cm
DT11-100X75
100cmx100cm
DT11-100X100
150cmx50cm
DT11-150X50
150cmx75cm
DT11-150X75
150cmx100cm
DT11-150X100
Dimensions of outer edge with aluminum flange
L1+120mmxL2+120mm
Remark:
1.The size of the safety mat is the net size without the aluminum edge, and the size error is ±6mm;
2.Accept non-standard size safety mat customization. The length of one side of non-standard size safety mat should be <3000mm, and the area should be ≤1.5m²;
3.Accept the design and customization of special-shaped safety mats, and the user needs to provide the floor plan of the protection area and technical requirements.The maximum area of special-shaped safety carpet is ≤3m².
Technical Parameters

model
DT11
Detection method
pressure sensing method
Power consumption
<20kg
Maximum allowable dynamic load
<200kg/cm²
Mechanical life
>3,000,000 times
Encapsulation and Surface Protection
PVC
ambient temperature
-20℃—+55℃
degree of protection
IP65
Maximum humidity (23 degrees)
95% (condensation)
Arrange classification

Response time
13ms
EN 1760-1 reset command
support
ISO 13849-1:2006
Cat.3
MTTFd
>30 years
B10d
6*10
Nop (accept)
52560/year
IEC 61508: PFHS
9.99*10 1/h(SIL3)
Selection of relays                                                                                                                                                                                      
safety relay Ter-A
safety relay for Dadisick Safety Light Curtains
Wiring diagram                                                                                                                                                                                          
1. Dual Channel 2-Wire R-Type Carpet (With Resistor) Safety Input, With Manual Reset
2. Dual Channel 4-Wire Carpet K-Type (Non Resistive) Safety Input With Manual Reset
3.Splice safety mats for connecting switch output mode safety controller
DOCUMENTS & DOWNLOADS                                                                                                                                                                  
CATALOGUE

DT11 series technical data sheet
CERTIFICATE
TÜV Certificate of Safety Mat and Safety Controller
Title
Sample Content
Title
Sample Content