OX-D2/OX-D3|The safety door switch with locking function|DADISICK

  • group nameSafety Switches

  • Min Order1 piece

  • brand nameDADISICK

  • modelOX-D2 & OX-D3

  • update timeSun, 05 May 2024 20:46:59 GMT

Paramtents

  • Full range of gold-plated contacts Configure 5 contact structures

  • Suitable for standard and small loads Adjust up to 8 directional key operation holes

  • IEC/EN60947-5-1 GB14048.5-2017

Packging & Delivery

  • Min Order1 piece

Briefing

Used for monitoring places such as safety doors and windows.

Detailed

Performance Specifications

Applicable standard
IEC/EN60947-5-1/GB14048.5-2017
Protection level*1
IP65/IP67 (EN60947-5-1 key operation hole)
Service life*2
More than 1 million machinery/more than 300,000 times of electricity
Rated insulation voltage (Ui)
400V
Rated impulse withstand voltage (Uimp)
4KV
Rated open thermal current (Ith)
8A
Use category
AC-15
Rated working voltage (Ue)
AC400V
Rated operating current (le)
2A
Rated limited short-circuit current
1000A
forced disengagement force
≥60N
Forced breakaway distance
≥10mm
Operating frequency
≤ 20 times/minute
Ambient temperature
-20°C~60°C (not freezing)
Environment humidity
Below85%RH
1. The above values are initial values.
2. The contacts of the switch are shared by standard and small loads, but the contacts that operate on a certain load cannot be connected to a load with a smaller capacity for use. Failure to do so may result in damage to the contact surface and reduced contact reliability.
3. Although the switch housing can prevent dust or water from entering, do not use the switch where foreign matter such as powder, water or medicine may enter the keyhole of the switch head, otherwise wear, damage or malfunction of the switch may occur.
4.The conditions for durability are an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.
DIMENSION                                                                                                                                                                                           
ACCESSORIES                                                                                                                                                                                           
SAFETY RELAY                                                                                                                                                                                           
safety relay
safety relay for Safety locking device
safety relay Ter-A
safety relay for Dadisick Safety Light Curtains
WIRING DIAGRAM                                                                                                                                                                                    
the safety door lock and QSRN diagram between 
the safety door lock and Ter-A wiring diagram between 
SAFETY DOOR HANDLES                                                                                                                                                                           
DOCUMENTS & DOWNLOADS                                                                                                                                                                  
CATALOGUE

Safety Locking Devices OX-D2 & OX-D3 series technical data sheet
3D
OX-D2 & OX-D3.3D-STP
CERTIFICATE
TUV-Certificate
UL Certificate
ROHS Certificate
CE Certificate
CE TYPE 4 Certificate
Trademark Registration Certificate

Company Business License